Congestion Detection, Avoidance, and Isolation
Configuration Examples for Congestion Detection, Avoidance,
and Isolation

Configuration Examples for Congestion Detection

This example shows how to configure the FCoE congestion drop timeout to the default value of 500 milliseconds
for a core port type in Cisco MDS NX-OS Release 8.1(1) and earlier releases:
switch# configure terminal
switch(config)# system default interface congestion timeout 500 mode core
This example shows how to configure the FCoE congestion drop timeout to the default value of 500 milliseconds
for a core port type in Cisco MDS NX-OS Release 8.2(1) and later releases:
switch# configure terminal
switch(config)# system timeout fcoe congestion-drop default mode core
This example shows how to configure the FCoE congestion drop timeout to the default value of 500 milliseconds
for an edge port type in Cisco MDS NX-OS Release 8.1(1) and earlier releases:
switch# configure terminal
switch(config)# system default interface congestion timeout 500 mode edge
This example shows how to configure the FCoE congestion drop timeout to the default value of 500 milliseconds
for an edge port type in Cisco MDS NX-OS Release 8.2(1) and later releases:
switch# configure terminal
switch(config)# system timeout fcoe congestion-drop default mode edge
This example shows how to configure the FCoE congestion drop timeout to the value of 200 milliseconds for
a core port type in Cisco MDS NX-OS Release 8.1(1) and earlier releases:
switch# configure terminal
switch(config)# system default interface congestion timeout 200 mode core
This example shows how to configure the FCoE congestion drop timeout to the value of 200 milliseconds for
a core port type in Cisco MDS NX-OS Release 8.2(1) and later releases:
switch# configure terminal
switch(config)# system timeout fcoe congestion-drop 200 mode core
This example shows how to configure the FCoE congestion drop timeout to the value of 200 milliseconds for
an edge port type in Cisco MDS NX-OS Release 8.1(1) and earlier releases:
switch# configure terminal

Configuration Examples for Congestion Detection, Avoidance, and Isolation