Cisco MDS 9000 Series Configuration Manual page 168

Interface
Hide thumbs Also See for MDS 9000 Series:
Table of Contents

Advertisement

Information About Congestion Detection
• Overutilization—Configuring port monitor with the Tx datarate and Rx datarate counters allow the
Cisco MDS 9000 Series Interfaces Configuration Guide, Release 8.x
150
----------------------------------------------------------------------------
ERROR STATISTICS INFORMATION FOR DEVICE DEVICE: FCMAC
----------------------------------------------------------------------------
Interface |
Range
| Error Stat Counter Name
|
-----------------------------------------------------------------------------
fc1/94
|F16_TMM_TOLB_TIMEOUT_DROP_CNT
fc1/94
|FCP_SW_CNTR_TX_WT_AVG_B2B_ZERO
fc1/94
|FCP_SW_CNTR_TX_WT_AVG_B2B_ZERO
fc1/94
|FCP_SW_CNTR_TX_WT_AVG_B2B_ZERO
fc1/1
|FCP_SW_CNTR_RX_WT_AVG_B2B_ZERO
fc1/94
|FCP_SW_CNTR_TX_WT_AVG_B2B_ZERO
MDS to issue alerts, syslog entries, and record entries in the output of the logging onboard datarate
command. In an all MDS environment, only Tx datarate is enough to determine overutilization. In
mixed environments, with other types of switches that do not support Tx datarate, configuring Rx
datarate can help to determine the ingress rate from a non-MDS switch.
Tx datarate and Rx datarate must be configured as follows and included in the active port-monitor
policy:
counter tx-datarate poll-interval 10 delta rising-threshold 80 event 4
falling-threshold 79 event 4
counter rx-datarate poll-interval 10 delta rising-threshold 80 event 4
falling-threshold 79 event 4
In the show logging log and show logging onboard datarate commands, the time an interface was
running at a high Tx utilization is the time from rising threshold to falling threshold.
switch# show logging log
2018 Aug 24 13:09:07 %PMON-SLOT1-3-RISING_THRESHOLD_REACHED: TX Datarate has reached
the rising threshold (port=fc1/4 [0x1003000], value=820766704) .
2018 Aug 24 13:09:09 %PMON-SLOT12-5-FALLING_THRESHOLD_REACHED: TX Datarate has
reached the falling threshold (port=fc12/11 [0x158a000], value=34050354) .
2018 Aug 24 13:09:18 %PMON-SLOT1-5-FALLING_THRESHOLD_REACHED: TX Datarate has reached
the falling threshold (port=fc1/4 [0x1003000], value=233513787) .
2018 Aug 24 13:09:42 %PMON-SLOT12-3-RISING_THRESHOLD_REACHED: TX Datarate has reached
the rising threshold (port=fc12/11 [0x158a000], value=878848923) .
2018 Aug 24 13:10:45 %PMON-SLOT12-5-FALLING_THRESHOLD_REACHED: TX Datarate has
reached the falling threshold (port=fc12/11 [0x158a000], value=387111312) .
switch# show logging onboard datarate
----------------------------
Module:
1
----------------------------
---------------------------------
Module: 1 datarate
---------------------------------
----------------------------
Congestion Detection, Avoidance, and Isolation
|
|
Time Stamp
|
Count
|MM/DD/YY HH:MM:SS
|
|
|1968490
|08/28/18 12:23:29
|3384
|08/28/18 12:23:29
|3346
|08/28/18 12:23:09
|3253
|08/28/18 12:22:49
|752
|08/28/18 12:22:49
|3160
|08/28/18 12:22:29

Hide quick links: