Setting Open and Close Modes
OPEN
1) If operator is in RUN mode, press CAL/RUN
2) Press SCROLL
key until display reads "OPEN MODE>MOM" or
SCROLL
"OPEN MODE>C-STP." Figure 10.
MOM=momentary contact, meaning you press and release the
O
P
N E
k
y e
a
d n
the door will continue to move until it reaches
OPEN
SE
its travel limit. (See NOTE)
C EA
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
3) Press SET/CLEAR
SET
key to toggle between "OPEN MODE>C-STP" or
CLEAR
"OPEN MODE>MOM" on the display.
4) Press a SCROLL
key to shift to a new function and lock in the setting.
SCROLL
CAL
5) Press CAL/RUN
key to return to run mode.
RUN
CLOSE
1) If operator is in RUN mode, press CAL/RUN
SC L
2) Press SCROLL
key until display reads "CLOSE MODE>MOM,"
SCROLL
"CLOSE MODE>C-STP" or "CLOSE MODE>C-REV." Figure 10.
CLEA
EN
MOM=momentary contact, meaning you press and release the
key and the door will continue to move until it reaches
CLOSE
CLOSE
SE
its travel limit. (See NOTE)
L AR
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
C-REV=constant contact-reverse, meaning if you release the key
prior to the door reaching its travel limit, the door will
reverse direction. (See NOTE)
SET
3) Press SET/CLEAR
key to toggle between "CLOSE MODE>C-STP" or
CLEAR
"CLOSE MODE>C-REV" or "CLOSE MODE>MOM" on the display.
4) Press a SCROLL
key to shift to a new function and lock in the setting.
SCROLL
5) Press CAL/RUN
CAL
key to return to run mode.
RUN
(Constant vs Momentary Contact)
CAL
key to enter calibration mode.
RUN
S O L
CLOSE
CAL
key to enter calibration mode.
LOSE
RUN
T
EN
ROLL
C L
LO E
www.geniecompany.com
NOTE: Momentary contact (MOM) or Constant Reverse (C-REV) may not be used
unless both the OPEN and CLOSE Limits have been set.
In situations where an external reversing device is either not installed or not
operating properly, Constant Contact (C-STP) MUST BE USED.
WARNING:
be used on the CLOSE button, a monitored external reversing device
such as a photocell system or sensing edge switch must be used.
See pages 5.8-5.10 for installation of entrapment protection devices.
AVERTISSEMENT:
commande à contact momentané sur le bouton FERMETURE, un
dispositif d'inversion externe surveillée tel qu'un système de
cellule photoélectrique ou un commutateur de détection de bord
doit être utilisé. Voir l'installation des dispositifs de protection
contre le coincement en pages 5.8-5.10.
NOTE: During adjustment of a Travel Limit, the Open and Close Modes will
automatically fail-safe to Constant Contact until the Limit has been set or reset.
At that time the Open and Close Modes will revert to their previous setting.