Genie GCL-J&H 1/2HP Installation Manual page 21

Standard duty operator
Table of Contents

Advertisement

Line Voltage Wiring Fig. 1
1)
Remove LINE VOLTAGE INPUT PLUG and install proper
fittings and 1/2"conduit.
2)
Route proper LINE VOLTAGE wires into operator.
3)
Locate LINE INPUT terminals on circuit board. Using
correct connectors, attach wires to LINE INPUTS, and GROUND
terminal.
Keep low voltage and line voltage wires separate.
Route all line voltage wires as shown.
Plug all unused conduit holes.
Figure 1
HIGH
VOLTAGE
INPUT PLUGS
(Right & Left)
HIGH
VOLTAGE
INPUT PLUGS
(Right & Left)
www.geniecompany.com
LINE INPUT
LINE
TERMINALS
GROUND
ROUTE HIGH VOLTAGE WIRING
IN THE SHADED AREA AS SHOWN
LINE INPUT
LINE
TERMINALS
GROUND
P
ROUTE HIGH VOLTAGE WIRING
IN THE SHADED AREA AS SHOWN
04-14
Three Phase
LINE IN
POWER CONNECTIONS
L1
L2
L3
LINE 1
LINE 2
LINE 3
GND
LINE IN
Single Phase
L1 / L1
N / L2
LINE
115V
(HOT) NEUTRAL
208V
LINE 1
LINE 2
230V
GND
5.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gcl-j&h 3/4hpGcl-j&h 1hp

Table of Contents