Control Panel Features - Westinghouse WGen12000 User Manual

12,000 running watts | 15,000 peak watts
Hide thumbs Also See for WGen12000:
Table of Contents

Advertisement

FEATURES

CONTROL PANEL FEATURES

3
2
1
8
7
Push Button Electric Start:
1
• Push for 1 second to automatically start the
engine.
• Push again to stop the engine.
Engine Control Switch/Battery Disconnect:
2
Switch to "Stop" to stop the engine. When in
"Stop" position it prevents the unit from drawing
power from the battery. Switch to "Run" before
starting engine.
Battery Charging Port: Charge the battery when
3
the unit is off with charger provided.
4
Smart Switch Outlet: Connects the Westinghouse
ST Switch (sold separately) to the control panel.
5
USB Duplex: Two 5V DC USB ports.
6
Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator.
120-Volt, 20-Amp Duplex Outlets
7
(NEMA 5-20R): Each outlet is capable of carrying
a maximum of 20 amps on a single receptacle or a
combination of both receptacles.
8
20-Amp Circuit Breakers: Each circuit breaker
limits the current that can be delivered through the
120-volt duplex outlets to 20amps.
9
120-Volt, 30-Amp Twist Lock Outlet
(NEMA L5-30R): Outlet can supply
120V up to 30 amps.
15
5
4
12
13
ON
OFF
9
10
11
10
120/240-Volt, 30-Amp Twist Lock Outlet
(NEMA L14-30R): Outlet can supply either
120V or 240V up to 30 amps.
6
11
120/240-Volt, 50-Amp Outlet (NEMA 14-50R):
Outlet can supply either 120V or 240V up
to 50 amps.
12
30-Amp Circuit Breaker: Circuit breaker limits
the current that can be delivered through the 120-
volt duplex outlets to 30amps.
13
30-Amp Circuit Breaker: Circuit breaker limits
the current that can be delivered through the
14
120/240-volt duplex outlets to 30amps.
14
Ground Terminal: The ground terminal is used to
ground the generator.
15
VFT Data Center: Press and release the mode
button to toggle between Voltage, Frequency,
Total Hour Meter and Run/Maintenance Timer.
The Run/Maintenance Timer displays the time
in hours and minutes each time the generator
is ran. The run timer resets to 00:00 when the
generator is shut off. Built into this run timer is a
maintenance reminder. When the new generator
is ran for 25 hours, the meter will display P25.
This is to remind you to change the oil after the
initial 25 hours of run time. When it displays P50,
it is time to clean the air filter. When it displays
P100 it is time change/clean the fuel filter, clean
the air filter, and change the oil.
Voltage
Frequency in hertz
Lifetime run hours
Run/Maintenance
Westinghouse Outdoor Power Equipment | 11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents