Loosen/tighten the allen on the microscope arm to adjust the spring
pressure . Turn the allen clockwise if the arm does not hold the microscope
up . Turn the allen counter clockwise if the arm does not allow the
microscope to come down .
ADJUST WELDING STYLUS POSITION
•
Loosen the screws on either side of the stylus holder .
•
Adjust the welding stylus to a 45-degree angle then slightly tighten the screws
on the sides just enough to hold the stylus in place at a 45-degree angle .
•
While looking through the microscope, slide the welding stylus forward and
backward until the tip of the stylus is in the center of your focus .
•
Now securely tighten the stylus holder by tightening the screw on the bottom of
the stylus holder .
ADJUST THE MICROSCOPE FOCUS
•
Twist the knob on the microscope forward and backward to raise and lower the head .
This will allow you to focus the microscope on the welding stylus .
•
Place your finger under the welding electrode to help judge the correct focus location .
Focus the microscope until the texture on the skin of your finger is clearly visible .
INSERT THE SUPPORT BAR
•
Find the support bar holder on the side of the L shaped stylus holder arm .
•
Pull off the black rubber end cap .
•
Unscrew the support bar tightening screw then insert the support bar .
•
Replace the rubber end cap .
Microscope LCD Filter Shutter
The microscope LCD filter shutter allows an unobstructed working view before welding and completely protects the user's
eyes during the welding process . The Orion's internal computer verifies the microscope LCD filter shutter has been closed
before allowing the weld to take place . In the case that the shutter does not close, the microscope lens is equipped with >UV
16 and >IR 16 for maximum eye protection .