Menu Level 3: Operating Mode - Dometic COOLAIR RT780 Installation Manual

Renault trucks sleeper and high sleeper driver cab air conditioners
Hide thumbs Also See for COOLAIR RT780:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
CoolAir RT780, SP950T
➤ Use the + and – buttons to set the value for low voltage shutdown. The
characteristic figures at second and third place on the display represent the
voltage (V) at which the unit is shut down:
Characteristic
figure
➤ Press the
✓ The set value is saved and is then used when the unit is restarted.
✓ You are now in menu level 2 again and can use the + and – buttons to switch
between menu levels.
8.4

Menu level 3: Operating mode

The unit always starts with a defined operating mode for room temperature. This
parameter can be configured:
➤ Start configuration mode (chapter "Starting and ending configuration mode"
on page 15).
✓ The first digit of the display shows the menu level and the second and third
show the parameter which can be set.
➤ Press the + button twice to switch to menu level 3.
➤ Press the
✓ The digits in the display flash until the parameter you entered is confirmed.
➤ Use the + and – buttons to set the mode with which the unit starts up:
Characteristic
figure
0
1
2
3
➤ Press the
✓ The set value is saved and is then used when the unit is restarted.
✓ You are now in menu level 3 again and can use the + and – buttons to switch
between menu levels.
EN
Low voltage
shutdown
1
22.2
2
22.4
3
22.6
4
22.8
5
22.9
button to confirm your entry.
button to change the parameters.
Operating mode
Automatic mode
Operating mode 1
Operating mode 2
Operating mode 3
button to confirm your entry.
Configuration of unit software
Characteristic
Low voltage
figure
shutdown
6
7
8
9
10
23.0
23.1
23.2
23.4
23.6
17