Recovery Water System; Tank And Vacuum Grid With Float Cleaning [Vantage 17 Battery - Cable] - Clarke Vantage 17 Service Manual

Battery/cable
Hide thumbs Also See for Vantage 17:
Table of Contents

Advertisement

RECOVERY WATER SYSTEM

TANK AND VACUUM GRID WITH FLOAT CLEANING [Vantage 17 Battery - 17 Cable]
1.
Drive the machine to the appointed disposal area.
2.
Check that the switches (5 and 6) are turned to "0".
3.
If necessary, empty the tank (43) by means of the hose (22).
4.
Lift the cover (41), then wash with clean water the cover, the tank (43) and the vacuum grid (46).
Drain the water in the tank through the hose (22).
5.
If necessary, release the fasteners (A) and open the grid (B), recover the float (C), clean all the components and then
reinstall them.
6.
Check the recovery water tank cover gasket (D) for integrity.
NOTE
The gasket (D) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (D) after removing it from its housing (E).
When assembling the new gasket, install its joint (F) in the central area, as shown in the figure.
7.
Check the gasket (G) bearing surface (D) for integrity and sealing capabilities.
8.
Check the compensation hole (H) for clogging.
NOTE
The hole (H) compensates the air in the cover interspaces, thus allowing the creation of vacuum in the recovery water
tank.
9.
Close the cover (41).
D
H
VANTAGE 17 Battery / Cable
SERVICE MANUAL
RECOVERY WATER SYSTEM
F
B
G
9097182000 - 11/2009
ENGLISH
S301372
25