ENGLISH
RECOVERY WATER SYSTEM
RECOVERY WATER SYSTEM
RECOVERY WATER TANK AND VACUUM GRID CLEANING, AND COVER GASKET CHECK
1.
Drive.the.machine.to.the.appointed.recovery.water.disposal.area.
2.
Turn.the.ignition.key.(80).to."0".
3.
Lift.the.cover.(A).to.washing.position.(L).
4.
Wash with clean water the cover (A), the tank (B) and the vacuum grid with automatic shut-off float (D).
Drain.the.water.in.the.tank.through.the.hose.(16).
5.
If necessary, release the fasteners (E) and open the grid (D), recover the float (F), clean all the components and then reinstall
them.
6.
Check.the.tank.cover.gasket.(G).for.integrity.
NOTE
The gasket (G) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If.necessary.replace.the.gasket.(G).by.removing.it.from.its.housing.(H)..When.assembling.the.new.gasket,.install.the.joint.(I).in.the.
rear central area, as shown in the figure.
7.
Check.that.the.seating.surface.(J).of.the.gasket.(G).is.integral.and.adequate.for.the.gasket.itself.
NOTE
The hole (K), allowing to compensate the air in the cover air gap, contributes to create vacuum in the tank.
8.
Close.the.cover.(A).
G
A
B
C
28
L
I
K
J
SERVICE MANUAL -
D
F
FOCUS
II L17 - S20 - L20 - L20 Cyl. - BOOST
®
G
H
E
E
L20
®
P100119