Vacuum System Motor Electrical Input Check [Vantage 17 Battery - Cable] - Clarke Vantage 17 Service Manual

Battery/cable
Hide thumbs Also See for Vantage 17:
Table of Contents

Advertisement

ENGLISH
SERVICE MANUAL
RECOVERY WATER SYSTEM
VACUUM SYSTEM MOTOR ELECTRICAL INPUT CHECK [Vantage 17 Battery - 17 Cable]
WARNING!
This procedure must be performed by qualified personnel only.
1.
Drive the machine on a level ground.
2.
Check that the switches (5 and 6) are turned to "0".
3.
If there is recovery water in the tank (43), drain it through the hose (22).
4.
Disconnect the vacuum hose (29) from the squeegee (17).
5.
Open the cover (12) and apply the cover stand (60).
6.
Grasp the recovery water tank (A) in the area (B) and lift it, as shown in the figure, then disconnect the vacuum hose (C)
from the tank and remove the tank (A) together with the hoses (D) and (E).
(Vantage 17 Cable) Loosen the clamp (I) and disconnect the hoses (J), then remove the waterproof cover (K).
WARNING!
Do not touch uncovered electrical components while performing the following steps.
7.
Place an ammeter (F) on one of the cables (G) of the vacuum system motor (H).
8.
Activate the vacuum system by turning the switch (6) to "I", then check that the vacuum system motor electrical input is
within the following limits:
Vantage 17 Battery:
14 to 17 A
Vantage 17 Cable - 230 V, 50 - 60 Hz:
2 to 2.5 A
Vantage 17 Cable - 115 V, 60 Hz:
4 to 4.5 A
Turn the switch (6) to "0".
If the electrical input is higher, perform the following procedures to detect and eliminate the cause of the abnormal input:
Check the motor carbon brushes;
If necessary, disassemble the motor and clean it carefully, then check the condition of its moving parts.
If the above-mentioned procedures do not lead to a correct electrical input, the motor must be replaced.
9.
Carry out steps from 4 to 8 in the reverse order.
26
9097182000 - 11/2009
B
C
A
D
VANTAGE 17 Battery / Cable
E
S301369C

Advertisement

Table of Contents
loading