Clarke Vantage 17 Service Manual page 55

Battery/cable
Hide thumbs Also See for Vantage 17:
Table of Contents

Advertisement

EB1 ELECTRONIC BOARD CONNECTIONS [Vantage 17 Battery] (continues)
EB1 LOWER 8 WAYS MODU1 CONNECTOR (C)
PIN
1
CT
2
BT
3
VT
4
S-
5
S+
6
V-
7
V+
8
BL
(*)
Depending on charger connection to the mains: only with charger switched ON => 0V (high res.) for red LED cathode.
(**)
> 40mV is considered brush motor overload by the board: it starts blinking LEDs on the control panel and it cuts off the
motor after a time relating to the overload misurement.
EB1 FASTONS (D - E)
PIN
CH
6,3
BL
4,8
(*)
Depending on charger connection to the mains: only with charger switched OFF => 24V
(**)
Depending on charger connection to the mains: only with charger switched ON => signal for red LED cathode.
Description
Electrom. switches common
Brush Electrom. Switch
Vacuum Electrom. Switch
- shunt
+ shunt
Power
Power
Not used
Description
Power from charger
not used
VANTAGE 17 Battery / Cable
SERVICE MANUAL
ELECTRICAL SYSTEM
Work conditions
A
B
24V
24V
floating
0V
floating
floating
0V
0V
0V
<40mV (**)
0V
0V
24V
24V
floating (*)
floating
Work conditions
A
B
24V (*)
24V (*)
floating (**)
floating
9097182000 - 11/2009
ENGLISH
C
24V
floating
0V
0V
0V
0V
24V
floating
C
24V (*)
floating
53

Advertisement

Table of Contents
loading