Regulating Water Flow; Machine Start And Stop - Clarke CA30 20B Instructions For Use Manual

Clarke ca30 20b automatic scrubbers instructions for use
Hide thumbs Also See for CA30 20B:
Table of Contents

Advertisement

Available languages

Available languages

C
SOLUTION TANK FILLING
CAUTION !
Only low foam, nonfl ammable detergents may be used. These detergents must be suitable for the use of scrubbers.
9.
Open the water inlet cover (27) and add water to solution tank. Do not overfi ll the tank. When preparing the cleaning solutions, please follow
the dilution rates supplied by the chemical manufacturer Water temperature must not exceed 40

REGULATING WATER FLOW

WARNING !
Regulating the ball valve handle (A, Figure 10) must be done under the condition
when the power switch (41) is in the "Off" position.
10.
The volume of the water fl ow may be adjusted through the ball valve handle (A, Figure
10) according to the amount of water required for your scrubbing application.

MACHINE START AND STOP

Starting the machine
1.
Complete the preparatory steps as outlined above.
2.
Press the power switch (41) to the "I" position.
3.
Use the squeegee handle (14) to lower the squeegee.
4.
Press the Vacuum switch (42) to the "I" position.
5.
Press the solution switch (44) to the "I" position. (Work simultaneously with the safety
switch (1) to control the solenoid valve.)
6.
Squeeze the on / off switch (1) and push to move the machine. When switches are
squeezed, the brush (29) will rotate, and the solution will fl ow.
CONSULTATION:
Each safety switch is capable of controlling independently the operation of the
brush. In use, it facilitates the control of the operation of the machine. Operators
are encouraged to fi nd the most comfortable position their hands.
7/2014
B
FIGURE 9
INSTRUCTIONS FOR USE
E
A
D
°
C.
56091130 - CA30 20B
ENGLISH - A
F
B
A
FIGURE 10
FIGURE 11
A - 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

510b

Table of Contents