G trip unit

Advertisement

ENGLISH
133 Second
134 Phase
135 Event Specific 1
136 Event Specific 2
137 Event 8
138 Year
139 Month
140 Date
141 Hour
142 Minute
143 Second
144 Phase
145 Event Specific 1
146 Event Specific 2
147 Event 9
148 Year
150 Date
151 Hour
152 Minute
153 Second
154 Phase
155 Event Specific 1
156 Event Specific 2
157 Event 10
158 Year
159 Month
160 Date
161 Hour
162 Minute
163 Second
164 Phase
165 Event Specific 1
166 Event Specific 2
167 Long Time Trip Count
168 Short Time Trip Count
169 Instantaneous Trip Count
170 Ground Fault Sum Trip Count
179 Shunt 1 Trip Count
180 Shunt 2 Trip Count
196 Software Rev
227 Breaker Position
228 Error Code Log
229 Error Code Log
230 Error Code Log
231 Error Code Log
232 Error Code Log
233 Error Code Log
234 Error Code Log
235 Error Code Log
236 Error Code Log
237 Error Code Log
238 Error Counter
239 Long Time pickup State
0-Not in Pickup, 1-Near Pickup, 2-In Pickup Read
------------------------------------------------------------------------------------------------------
Communication Parameters Function 5
Reg.
Parameter
Values
103 Save Real Time Clock Registers
104 Read Real Time Clock Registers
105 Save EPROM Data
107 Upload to BIM
108 Trip Breaker
109 Reduced Instantaneous
112 Relay 1 State
113 Relay 2 State
116 Clear All Events
117 Clear EPROM
118 Clear Energy Total
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
1-CLOSE, 0-OPEN
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
1 to 10
Read
-
-
-
-
0- Reset, 1- Trip
0- Off, 1- ON
0- Off, 1- ON
0- Off, 1- ON
-
-
-
TRIP UNIT
2.5 Kommunikations-Register
DEUTSCH
Kommunikationsparameter Funktion 2
Nr. Bezeichnung
Wert
5
Relais 1 Status
0- AUS, 1- EIN
6
Relais 2 Status
0- AUS, 1- EIN
9
Eingabe 1 Status
0- AUS, 1- EIN
10 Eingabe 2 Status
0- AUS, 1- EIN
27 Schalterstellung
0- AUS, 1- EIN
34 Einschubträgeranzeige
0- AUS, 1- EIN
35 Ausfahrtechnik
0- AUS, 1- EIN
44 Fernschliessung
0- AUS, 1- EIN
------------------------------------------------------------------------------------------------------
Kommunikationsparameter Funktion 3
Nr. Bezeichnung
Wert
2
ERD Schutz Sum Aktiv
0- Inaktiv,
5
Nr. der Pole
0- 3 Pole,
7
Vollmessung Aktiv
0- Inaktiv,
8
Neutral Stellung
0- Inaktiv,
10 Langzeit Schutz Aktiv
0-Inaktiv,
18 Vorschrift Standard
0-UL,
19 Schaltertyp
8- EntelliGuard
20 GTU Modeltyp
4-GTU ACB
22 Stromwandler Werte
1-150A
2-200A
3-225A
4-400A
5-600A
6-800 A
7-1000A
35 ZSI Aktiv
0-Inaktiv, 1-GT-ST (Z),
37 Einschaltstromauslöser MCR Level Low 16 bits
38 Einschaltstromauslöser MCR Level Hoch 16 bits
39 HSISC Level Low 16 bits
---
40 HSICS Level Hoch 16 bits
---
81 Schnellauslösung
0-Inaktiv,
98 Schalterseriennummer
- Low 16 bits
99 Schalterseriennummer
- High 16 bits
107 Red. Schnellauslösung
0- Inaktiv,
202 EntelliGuard Ie Einstellung
0- undef.
1- 250,
2- 280,
3- 315,
4- 350,
5- 400,
6- 450,
7- 500,
8- 560,
9- 605,
10- 610,
11- 615,
12- 630,
13- 720,
14- 768,
15- 776,
16- 784,
17- 800,
18- 900,
19- 960,
20- 970,
21- 980,
22-1000,
206 Neutralleiter Schutz
0- 50%,
207 ZSI Kombination
0
1-ERD
2-ERD&ST
3-ST
208 PT Primärspannung
120- 600
209 PT Anschluss
0- Ph-Null
210 Passwortschutz
0 bis 20 16- Lock 19- Unlock
211 Modbus Nebenadresse
8 bit Wert
213 Kommunikationseinstellung 0- 300-8N2
1- 600-8N2
2- 1200-8N2 9- 1200-8O1 16- 1200-8E1
3- 2400-8N2 10- 2400-8O1 17- 2400-8E1
EntelliGuard G
Lesen / Schreiben
Lesen
Lesen
Lesen
Lesen
Lesen
Lesen
Lesen
Lesen
Lesen / Schreiben
1-Aktiv
Lesen
1- 4 Pole
Lesen
1-Aktiv
Lesen
1-Aktiv
Lesen
1- Aktiv
Lesen
1-IEC,
2-ANSI
Lesen
Lesen
8-1200A
15-5000A
Lesen
9-1600A
16-6000A
10-2000A
17-630A
11-2500A
18-1250A
12-3000A
19-6400A
13-3200A
20-Uni. Zubehör
14-4000A
2-GR-ST-Inst (T)
Lesen
---
Lesen
---
Lesen
Lesen
Lesen
1-15X schaltbar
Lesen
-
Lesen
-
Lesen
1-Aktiv
Lesen
23- 1125,
46- 3072,
Beides
24- 1196,
47- 3104,
25- 1210,
48- 3136,
26- 1225,
49- 3200,
27- 1250,
50- 3840,
28- 1280,
51- 3880,
29- 1440,
52- 3920,
30- 1536,
53- 4000,
31- 1552,
54- 4800,
32- 1568,
55- 4850,
33- 1600,
56- 4900,
34- 1800,
57- 5000,
35- 1920,
58- 6144,
36- 1940,
59- 6208,
37- 1960,
60- 6272,
38- 2000,
61- 6400,
39- 2250,
62- 160,
40- 2400,
63- 180,
41- 2425,
64- 380,
42- 2450,
65- 385,
43- 2500,
66- 390,
44- 2560,
45- 2880,
1- 63%,
2- 100%
Beides
Beides
4-Instantaneous
5-ERD and Inst
7-ERD, ST and Inst
Beides
1- Ph-Ph
Beides
Beides
Beides
7- 300-8O1
14- 300-8E1 Beides
8- 600-8O1
15- 600-8E1
2
.5
2-37

Advertisement

loading