General Specifications - Fluke 287 Getting Started

True-rms digital multimeters
Hide thumbs Also See for 287:
Table of Contents

Advertisement

General Specifications

Maximum voltage between any Terminal and Earth Ground: 1000 V
W Fuse Protection for mA or μA inputs .............0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
W Fuse Protection for A input.............................11 A, 1000 V FAST Fuse, Fluke specified part only
Battery Type...........................................................6 AA Alkaline batteries, NEDA 15A IEC LR6
Battery Life.............................................................100 hours minimum. 200 hours in Logging mode
Temperature
Operating.............................................................-20 °C to 55 °C
Storage................................................................-40 °C to 60 °C
Relative Humidity ..................................................0 % to 90 % (0 °C to 37 °C), 0 % to 65 % (37 °C to 45 °C), 0 % to 45 % (45 °C to 55°C)
Altitude
Operating.............................................................3,000 m
Storage................................................................10,000 m
Temperature Coefficient .......................................0.05 X (specified accuracy) /°C (<18 °C or >28 °C)
Vibration.................................................................Random Vibration per MIL-PRF-28800F Class 2
Shock......................................................................1 meter drop per IEC/EN 61010-1 2
Size (HxWxL)..........................................................8.75 in x 4.03 in x 2.38 in (22.2 cm x 10.2 cm x 6.0 cm)
Weight ....................................................................28.0 oz (871 g)
Safety Standards
US ANSI ..............................................................Complies with ANSI/ISA 82.02.01 (61010-1) 2004
CSA .....................................................................CAN/CSA-C22.2 No 1010-1-04 to 1000 V Measurement Category III and 600 V
UL........................................................................UL 61010 (2003)
CE European.......................................................IEC/EN 61010-1 2
Measurement Category IV, Pollution Degree 2