287/289
Getting Started

MIN MAX, Recording, and Peak Specifications

Function
200 ms to 80% (dc function)
MIN MAX, Recording
350 ms to 80 % (ac function)
250 μS (peak)
Peak
[1]
For repetitive peaks; 2.5 ms for single events.
Burden Voltage (A, mA,
Function
mA, μA
A
16
Nominal Response
[1]
μ
A)
500 μA
5000 μA
50.000 mA
400.00 mA
5.0000 A
10.000 A
Specified accuracy ±12 counts for changes >425 ms in duration in manual
range.
Specified Accuracy ±40 counts for changes >1.5 s in duration in manual
range.
Specified accuracy ±100 counts up to 5,000 count (full range) reading. For
higher peak reading (to 12,000 counts), specified accuracy ±2 % of
reading.
Range
102 μV/ μA
102 μV/ μA
Accuracy
Burden Voltage
1.8 mV/mA
1.8 mV/mA
0.04 V/A
0.04 V/A