Analog Inputs
Static (Steady-State) Object Number: 30
Change Event Object Number: 32
Analog Input Deadband: 34
Static Variation reported when variation 0 requested: 1 (32-Bit Analog Input with Flag)
Change Event Variation reported when variation 0 requested: 1 (32-Bit Analog Change Event w/o Time)
Analog Input Reporting Deadband Variation reported when variation 0 requested: 1 (16-Bit)
Point
Description
Index
184 CB Wear A
185 CB Wear B
186 CB Wear C
187 CB Wear A Remaining
188 CB Wear B Remaining
189 CB Wear C Remaining
190 CB Wear Minimum
198 I1 Last Trip
199 I2 Last Trip
200 IEq Last Trip
201 IUn Last Trip
203 Thermal Capacity
204 Thermal Capacity Available
205 Last Motor Start Tim
206 Thermal Capacity Last Start
207 Last Start Max Current
208 Last Start Min Voltage
209 Time To Trip
210 Thermal Time To Star
211 CurrentMotorRunTimeM
212 MotorTotalRunTimeMet
213 AverageMotorRunTimeM
214 Time Before Run Time
215 MotorStopTimeMeter
216 MotorNumStartsMeter Meter
217 MotorEmStartsMeter Meter
218 A66NumberOfStartsMet
219 RestartInhibitTimerM
220 Temp1
221 Temp2
222 Temp3
223 Temp4
224 Temp5
© 2018 Siemens Protection Devices
Chapter 4 - 7SR105 Rho · Data Communications Definitions
or 2 (16-Bit Analog Input with Flag)
or 3 (32-Bit Analog Input w/o Flag)
or 4 (16-Bit Analog Input w/o Flag)
or 5 (Single Precision, floating point Analog Input with Flag)
or 2 (16-Bit Analog Input w/o Time)
or 3 (32-Bit Analog Input with Time)
or 4 (16-Bit Analog Input with Time)
or 5 (Single Precision, floating point Analog Input w/o Time)
or 7 (Single Precision, floating point Analog Input with Time)
or 2 (32-Bit)
or 3 (Single Precision, floating point)
Default
Default
Change Event
Variation
Variation
Assigned Class
Static
(1, 2, 3 or none)
Object 30
Object 32
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
1
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
0,3
2
Default
Default
Event
Multiplier
3
0.000
3
0.000
3
0.000
3
1.000
3
1.000
3
1.000
3
1.000
3
1.000
3
1.000
3
1.000
3
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
4
1.000
Chapter 4 - Page 57 of 70
Default
Deadband
1000000.000
1000000.000
1000000.000
1.000
1.000
1.000
1.000
Disabled
Disabled
Disabled
Disabled
10.000
10.000
1.000
1.000
100.000
10.000
10.000
10.000
60.000
60.000
60.000
10.000
60.000
1.000
1.000
1.000
10.000
1.000
1.000
1.000
1.000