Siemens 7SR105 Rho User Manual page 135

Motor protection relay
Table of Contents

Advertisement

7SR105 Rho Technical Manual
OBJECT
Object
Variation
Number
Analog Change Event
32
0
32Bit-Analog Change Event
32
1
16Bit-Analog Change Event
32
2
32Bit-Analog Change Event
32
3
4 (default -
16Bit-Analog Change Event
32
see note 1)
32
5
Analog Change Event
32
6
Analog Change Event
32
7
Analog Change Event
32
8
Analog Change Event
Frozen Analog Event
33
0
32-Bit Frozen Analog Event
33
1
16-Bit Frozen Analog Event
33
2
32-Bit Frozen Analog Event
33
3
16-Bit Frozen Analog Event
33
4
Short Floating Point
33
5
Frozen Analog Event
Long Floating Point
33
6
Frozen Analog Event
Extended Floating Point
33
7
Frozen Analog Event
Analog Input Deadband
34
0
(Variation 0 is used to
request default variation)
34
1
2 (default -
34
see note 1)
Short Floating Point
34
3
Analog Input Deadband
Chapter 4 - Page 42 of 70
Function Codes
Description
(dec)
1 (read)
- Any Variation)
1 (read)
(without Time)
1 (read)
(without Time)
1 (read)
(with Time)
1 (read)
(with Time)
short floating point
1 (read)
(without Time)
long floating point
1 (read)
(without Time)
short floating point
1 (read)
(with Time)
long floating point
1 (read)
(with Time)
- Any Variation
(without Time)
(without Time)
(with Time)
(with Time)
1 (read)
1 (read)
16 bit Analog
Input Deadband
2 (write)
1 (read)
32 bit Analog
Input Deadband
2 (write)
1 (read)
REQUEST
(Library will parse)
Qualifier Codes
(hex)
06 (no range, or all)
07, 08 (limited qty)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
06 (no range, or all)
07, 08 (limited qty)
(unsol. resp)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
07, 08 (limited qty)
17, 27, 28 (index)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
© 2018 Siemens Protection Devices
RESPONSE
(Library will respond with)
Function
Qualifier Codes
Codes
(hex)
(dec)
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
129
(response)
17, 28 (index)
130
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)
00, 01 (start-stop)
129
17, 28 (index
(response)
- see note 2)