  • Page 1 Smart SAM2W User Guide V1.2 Smart SAM2W User Guide Ver1.2...
  • Page 2 Smart SAM2W User Guide V1.2 Revision History Version Modified By Date Description 18/04/2012 Initial version 28/11/2012 Updated to Smart SAM2W 09/10/2013 New Packaging Information Ver1.2...
  • Page 3: Table Of Contents

    Smart SAM2W User Guide V1.2 Contents Introduction ................................2 Safety Precautions .............................3 Radio Frequency Exposure - SAR ........................4 WEEE Directive 2002/96/EC, Disposal Of Old Electronic Equipment ............5 Packaging ................................6 5.1 Contents ................................6 5.2 Packaging Box ..............................6 5.3 Production Label ..............................7 Functionality ................................8 6.1 General ................................8...
  • Page 4: Introduction

    The Smart SAM2W also provides Open-AT platform for different applications. The Smart SAM2W is designed for both mobile and fixed M2M applications. It has an RJ45 socket for input voltage and the serial RS232 signals, an FME-male for antenna connection, a SIM holder and an LED indicator.
  • Page 5: Safety Precautions

    Smart SAM2W User Guide V1.2 2 Safety Precautions The following safety precautions must be observed whenever the Smart SAM2W modem is in operation or in service. Failure to comply with these precautions violates the safety standards of the design, manufacture...
  • Page 6: Radio Frequency Exposure - Sar

    This is because the transceiver is designed to use minimum power to connect to the network. The Smart SAM2W modem is approved to use in applications where the antenna is placed more than 21cm from the body.
  • Page 7: Weee Directive 2002/96/Ec, Disposal Of Old Electronic Equipment

    It must be placed at an appropriate collection point for the recycling of electrical and electronic equipments. By ensuring the correct disposal of this equipment, it will help the environment and human health. Recycling will help to conserve natural resources. The Smart SAM2W product is RoHS compliant Ver1.2...
  • Page 8: Packaging

    The data cable is 2m long The label size is 50mm x 33mm A power supply is available on request. It is recommended that the Smart SAM2W is powered using a 12Vdc/1A power supply. The antenna is also available on request. Please make sure the correct antenna is used to get optimised performance from the Smart SAM2W.
  • Page 9: Production Label

    : Intercel Pty Ltd Made by : ASSSMRTS2W Part number SAM2WAMR The production part number is located at the back of the Smart SAM2W, which includes: The product model The software version The hardware version The IMEI number The manufacturer The part number Ver1.2...
  • Page 10: Functionality

    The Smart SAM2W also contains the power assist circuitry. This PA circuitry is optionally loaded and activated when the power supply does not have enough power to assist the Smart SAM2W when it is in a CSD call or in a GPRS session. It also helps to send the last-gasp message back to the server when power is cut off to the modem.
  • Page 11: Rj45 Socket

    Description Input Voltage 5Vdc - 32Vdc Data Carrier Detect Data Terminal Ready Common Ground Serial Data out of the Smart SAM2W Serial Data into the Smart SAM2W Clear to Send Ready to Send 6.3 FME-Male 50Ω Antenna Connector The FME male antenna connector is a 50Ω impedance antenna connector. The antenna used for the Smart SAM2W must have 50Ω...
  • Page 12: Data Cable

    The data cable is 2m long. It consists of an RJ45 plug, a DB9-female connector and a 2-wire input power. Signals RJ45 Description Data Carrier Detect Serial Data out of the Smart SAM2W Serial Data into the Smart SAM2W Not Used Common Ground Ready to Send...
  • Page 13: Electrical Characteristics

    Smart SAM2W User Guide V1.2 7 Electrical Characteristics 7.1 Power Consumption Network search 65mA @ 12V Idle mode 40mA @ 12Vdc Connected mode 90mA @ 12Vdc GPRS PSD transfer 245mA @ 12Vdc Peak current during the 577µs transmission pulse 500mA @ 12V 7.2 RF Bands...
  • Page 14: Main Antenna Specifications

    Smart SAM2W User Guide V1.2 7.5 Main Antenna Specifications Max cable loss 0.5dBm 50Ω Impedance VSWR 1.5 : 1 The maximum antenna gain recommended for consideration against RF exposure and ERP/EIRP limits, is: In Cellular band : 5dBi In PCS band : 4dBi 7.6 Environmental Characteristics...
  • Page 15: The Amr Tcp/Ip Stack

    8 The AMR TCP/IP STACK 8.1 Descriptions The AMR TCP/IP stack allows the Smart SAM2W modem to make/receive GSM data call and at the same time enables the modem to act as a GPRS TCP server/client and UDP server/client. When powered up this stack will automatically activate a GPSR connection then create 3 sockets;...
  • Page 16: Tcp/Udp/Ip At Commands

    Smart SAM2W User Guide V1.2 8.2 TCP/UDP/IP AT Commands The TCP/UDP/IP stack provides some AT commands for setting up communication parameters, software upgrade, checking status and more. AT$SETGPRS Use to set up the GPRS parameters required for GPRS connection. This command can be sent from serial port, over SMS, GSM data call and TCP GPRS.
  • Page 17 Smart SAM2W User Guide V1.2 AT$SETTCP Use to setup parameters for TCP data socket. This command is for serial port entry only. AT$SETTCP=? $SETTCP: Port(1-65535), TimeOutTrigger(0-65535),Server(120) AT$SETTCP? $SETFTP: <TCPPort>,<TimeOutTrigger>,<TCPServ> AT$SETTCP=<TCPPort>,<TimeOutTrigger>,<TCPServ> <TCPPort> : From 1 to 65535, is port number for both local TCP server and remote TCP server, default is10000.
  • Page 18 Smart SAM2W User Guide V1.2 AT$SETUDP Use to setup parameters for UDP data socket. This command is for serial port entry only. AT$SETUDP=? $SETUDP: Port(1-65535),TimeOutTrigger(0-65535),Server(120) AT$SETUDP? $SETUDP: <UDPPort>,<TimeOutTrigger>,<UDPServ> AT$SETUDP=<UDPPort>,<TimeOutTrigger>,<UDPServ> <UDPPort> : From 1 to 65535, is port number for both local UDP server and remote UDP server, default is 20000.
  • Page 19 Smart SAM2W User Guide V1.2 AT$TCPMODE=0 Modem does not make TCP connection to remote TCP server after connected to GPRS. AT$TCPMODE=1 Modem makes TCP connection to remote TCP server after connected to GPRS. Default is 0. AT$TCPMODE? $TCPMODE: 0 AT$GSMMODE Set modem operating mode.
  • Page 20 Smart SAM2W User Guide V1.2 AT$SMSNUMBER Set phone number to receive alarm SMS when modem looses power (for Super CAP hardware only), this command is for serial port entry only. AT$SMSNUMBER=”0418505361” AT$SMSNUMBER? $SMSNUMBER: 0418505361 AT$SERIALMODE Set modem serial mode. This command is for serial port entry only.
  • Page 21 Smart SAM2W User Guide V1.2 AT$PARAMETERS Remote request and setting of parameters over SMS, TCP GPRS and GSM data call. AT$PARAMETERS=<tcpport>,<tcptimeouttrigger>,<tcpserver>,<tcpmode>,<udpport>, <udptimeouttrigger>, <udpserver>,<pingip>,<pinginterval>,<serialmode>,<gsmmode>, <smsnumber> AT$PARAMETERS? To request for modem parameters? AT$PARAMETERS=10000,100,”255.255.255.255”,0,20000,100,”255.255.255.255”, ”192.168.80.40”,60,0,0,”0418505361” AT$FTPDOWN Use to send FTP (File Transfer Protocol) parameters to modem and request downloading of new firmware from FTP server, this command can be sent from serial port, over SMS and TCP GPRS.
  • Page 22 Smart SAM2W User Guide V1.2 AT$VERSION This command return the TCP/IP software version, this command can be sent from serial port, over SMS, TCP GPRS and GSM data call. AT$VERSION $VERSION: AMR 1.0 OpenAT6.51 130912 11:40 AT$RESET Use to remotely reset the modem, normally after sending of new parameters, this command can be sent over SMS, TCP GPRS and GSM data call.
  • Page 23 Smart SAM2W User Guide V1.2 AT$SHOWALL Use to show all settings of the modem, this command can only be sent from the serial port. AT$SHOWALL $VERSION: AMR 1.0 OpenAT6.51 130912 11:40 $IP: 10.64.24.1 $SETGPRS: "mach2","intercel","mach" $SETTCP: 10000,100,"255.255.255.255" $TCPMODE: 0 $SETUDP: 20000,100,"10.64.24.2"...
  • Page 24 Smart SAM2W User Guide V1.2 AT$GETLOG Use to retrieve log message file from modem, there is a maximum of 250 messages, this command can be sent from serial port, over GSM data call and TCP GPRS. AT$GETLOG 001 2011.12.02 17:51:52 17935 - Caller ID: 0395612959 002 2011.12.02 17:51:55 07700 - Modem send ATA to answer data call...
  • Page 25: Remote Escape Sequence

    Smart SAM2W User Guide V1.2 9 Remote Escape Sequence During GSM data call the modem can be switched into AT command mode remotely by sending the sequence <Enter><Enter><Enter> ( hex sequence 0x0D 0x0D 0x0D) within one second, a guard or gap time of one second for the first <Enter>...
  • Page 26: Specific Requirements

    Smart SAM2W User Guide V1.2 10 Specific Requirements -Modem reset when it failed to connected to GPRS, when change setting with AT$SETGPRS it best to leave the SIM holder open, it give the user 5 minutes to enter new settings before reset.