  • Page 1 Smart SAM2S User Guide V1.4 Smart SAM2S User Guide Ver1.4...
  • Page 2 Smart SAM2S User Guide V1.4 Revision History Version Modified By Date Description 18/04/2012 Initial version 19/06/2013 Update 09/10/2013 New Packaging Information 25/11/2014 Software Update 27/01/2015 Added AT$LGSMS Ver1.4...
  • Page 3: Table Of Contents

    7.3 Receive Sensitivity ............................11 7.4 Conducted Transmit Power ..........................11 7.5 Main Antenna Specifications ........................12 7.6 Environmental Characteristics ........................12 The Smart SAM2S TCP/IP Operation ......................13 8.1 Communication Sockets ..........................13 8.2 TCP/IP AT$ Commands ..........................14 8.3 CSD Call Escape Sequence ........................21 Firmware Upgrade ............................22 9.1 Firmware Upgrade for the 2G Module ......................22...
  • Page 4: Introduction

    The Smart SAM2S comes in 2 selectable options: The Smart SAM2S is designed for both mobile and fixed M2M applications. It has an RJ45 socket for input voltage and the serial RS232 signals, an FME-male for antenna connection, a SIM holder and an LED indicator.
  • Page 5: Safety Precautions

    Smart SAM2S User Guide V1.4 2 Safety Precautions The following safety precautions must be observed whenever the Smart SAM2S modem is in operation or in service. Failure to comply with these precautions violates the safety standards of the design, manufacture...
  • Page 6: Radio Frequency Exposure - Sar

    This is because the transceiver is designed to use minimum power to connect to the network. The Smart SAM2S modem is approved to use in applications where the antenna is placed more than 21cm from the body.
  • Page 7: Weee Directive 2002/96/Ec, Disposal Of Old Electronic Equipment

    It must be placed at an appropriate collection point for the recycling of electrical and electronic equipments. By ensuring the correct disposal of this equipment, it will help the environment and human’s health. Recycling will help to conserve natural resources. The Smart SAM2S product is RoHS compliant Ver1.4...
  • Page 8: Packaging

    The data cable is 2m long The label size is 50mm x 33mm A power supply is available on request. It is recommended that the Smart SAM2S is powered using a 12Vdc/1A power supply. Various antenna options are also available on request. Please make sure the correct antenna is used to get optimised performance from the Smart SAM2S.
  • Page 9: The Production Label

    352679010 049570 : Intercel Pty Ltd Made by : ASSSMRTS2S Part number The production part number is located at the back of the Smart SAM2S, which includes: The product model The software version The hardware version The IMEI number The manufacturer The part number Ver1.4...
  • Page 10: Functionality

    6 Functionality 6.1 General The Smart SAM2S modem consists of an RJ45 socket for serial port and input power, an FME male antenna connector and a SIM holder. The LED indicator, located next to the SIM holder, indicates the Smart SAM2S operating status.
  • Page 11: Rj45 Socket

    Smart SAM2S User Guide V1.4 6.2 RJ45 Socket Signals Description Input Voltage 5Vdc - 32Vdc Data Carrier Detect Data Terminal Ready Common Ground Serial Data out of the SAM Serial Data into the SAM Clear to Send Ready to Send 6.3 FME-Male 50Ω...
  • Page 12: Data Cable

    The data cable is 2m long. It consists of an RJ45 plug, a DB9-female connector and a 2-wire input power. Signals RJ45 Description Data Carrier Detect Serial Data out of the Smart SAM2S Serial Data into the Smart SAM2S Not Used Common Ground Clear to Send...
  • Page 13: Electrical Characteristics

    Smart SAM2S User Guide V1.4 7 Electrical Characteristics 7.1 Power Consumption Network search 70mA @ 12V Idle mode 45mA @ 12Vdc Connected mode 95mA @ 12Vdc GPRS PSD transfer 250mA @ 12Vdc Peak current during the 577µs transmission pulse 1.2A @ 12V 7.2 RF Bands...
  • Page 14: Main Antenna Specifications

    Smart SAM2S User Guide V1.4 7.5 Main Antenna Specifications Max cable loss 0.5dBm 50Ω Impedance Max allowed VSWR The maximum antenna gain recommended for consideration against RF exposure and ERP/EIRP limits, is: In Cellular band : 5dBi In PCS band : 4dBi 7.6 Environmental Characteristics...
  • Page 15: The Smart Sam2S Tcp/Ip Operation

    Smart SAM2S User Guide V1.4 8 The Smart SAM2S TCP/IP Operation The Smart SAM2S has a MCU (Microcontroller) to control the 2G module PHS8-P, the Smart SAM2S can be operating in there different modes, defined by parameter SAMMODE: -SAMMODE=0, modem is in dumb mode, when power on the MCU turn on the 2G module, check its baud...
  • Page 16: Tcp/Ip At$ Commands

    Smart SAM2S User Guide V1.4 UDP AT Command: Socket connection allows a user from the host computer to send AT commands to the modem and receive its responses, and socket also can be used for remote firmware update. 8.2 TCP/IP AT$ Commands Communications parameters are stored in Flash using AT$PARAMETERS.
  • Page 17 Smart SAM2S User Guide V1.4 AT$PARAMETERS=APN=telstra.extranet,USERNAME=intercel,PASSWORD=mach,LTCPPORT=10000,RT CPIP=203.45.1.236,RTCPPORT=10000,TCPMODE=,LUDPPORT=20000,RUDPIP=203.45.1.236,RUDPPO RT=20000,POLLPERIOD=60,SBREAKTIME=100,MBREAKTIME=5,BAUDRATE=115200,DATALEN=8,PAR ITY=NONE,SAMMODE=0 Saved parameters to flash... Or a few parameters or one at a time. AT$PARAMETERS=APN=telstra.extranet,USERNAME=intercel,PASSWORD=mach Saved parameters to flash... AT$PARAMETERS=LTCPPORT=10000,RTCPIP=203.45.1.236,RTCPPORT=10000,TCPMODE=,LUDPPO RT=20000,RUDPIP=203.45.1.236,RUDPPORT=20000 Saved parameters to flash... AT$PARAMETERS=POLLPERIOD=60,SBREAKTIME=100,MBREAKTIME=5,BAUDRATE=115200,DATALE N=8,PARITY=NONE Saved parameters to flash... AT$PARAMETERS=SAMMODE=0 Saved parameters to flash...
  • Page 18 Smart SAM2S User Guide V1.4 BAUDRATE: 115200 DATALEN: 8 PARITY: NONE POLLPERIOD: 60 SBREAKTIME: 100 MBREAKTIME: 5 SAMMODE: 0 AT$UDPCONNECT If modem is already allocated an IP address, this command will put the modem in UDP data mode, modem DCD pin go high, data from serial will be packetized into UDP packet and send to remote UDP server (UDP settings must be set prior), modem will return to AT Command mode if it receiving no UDP data in 30 seconds.
  • Page 19 Smart SAM2S User Guide V1.4 DDNSSERVER=DDNS server DDNSSTRING: Only need to change from default in some circumstances with Intercel support DDNSAUTH: Only need to change from default in some circumstances with Intercel support DDNSAGENT: Only need to change from default in some circumstances with Intercel support PDNSIP=Primary DNS, leave blank if not using your own DNS server, not a requirement for DDNS.
  • Page 20 Smart SAM2S User Guide V1.4 Connecting to DDNS dynupdate.no-ip.com ..Connected to DDNS dynupdate.no-ip.com HTTP/1.1 200 OK Date: Tue, 02 Sep 2014 00:33:32 GMT Server: Apache/2 Content-Location: update.php Vary: negotiate TCN: choice Content-Length: 19 Connection: close Content-Type: text/plain; charset=UTF-8 good 123.209.169.62 DDNS host intercelau.ddns.net updated with 123.209.169.62...
  • Page 21 Smart SAM2S User Guide V1.4 AT$ACCESS=IPBLOCK=1,REMOTEIP1=10.64.24.2,REMOTEIP2=,REMOTEIP3=,REMOTEIP4=,SMSBLO CK=1,REMOTESMS1=0413586218,REMOTESMS2=,REMOTESMS3=,REMOTESMS4=,DIALBLOCK=1,R EMOTEDIAL1=0395612959,REMOTEDIAL2=,REMOTEDIAL3=,REMOTEDIAL4= Saved parameters to flash... AT$ACCESS? $ACCESS: IPBLOCK: 1 REMOTEIP1: 10.64.24.2 REMOTEIP2: REMOTEIP3: REMOTEIP4: SMSBLOCK: 1 REMOTESMS1: 0413586218 REMOTESMS2: REMOTESMS3: REMOTESMS4: DIALBLOCK: 1 REMOTEDIAL1: 0395612959 REMOTEDIAL2: REMOTEDIAL3: REMOTEDIAL4: AT$LGSMS Use to program parameters for last gasp SMS.
  • Page 22 Smart SAM2S User Guide V1.4 LGSMSNO: +61418505361 AT$LOGIN Use to setup login details for remote sending of AT commands, parameters and software updating; password is encrypted so remote login required PC software SAM2S Terminal. AT$LOGOFF Use to log off remote access instantly; modem will lock out remote access that has been idled for 120 seconds.
  • Page 23: Csd Call Escape Sequence

    -In SAMMODE=2, the MCU take about 20 seconds to set up the 2G module , the modem only response to AT commands from serial port after setting up is finished. -In SAMMODE 1 and 2 if the Smart SAM2S modem is powered up without a SIM card it will go into AT command mode after 20 seconds.
  • Page 24: Firmware Upgrade

    Smart SAM2S User Guide V1.4 9 Firmware Upgrade 9.1 Firmware Upgrade for the 2G Module The module’s firmware can be upgraded over the serial or USB port using the dedicated Upgrade Program running on PC, if using USB ,the 2G module’s driver must be installed on the PC beforehand.