Advertisement

Quick Links

Document history
11th Feb 2013: Start
th
08
Oct. 2013 added new packaging and label
st
21
July 2014
added SAMMODE
02 Sep 2014 added DDNS, security features
29 Sep 2014 added AT$UDPONLINE,AT$SMSTOSERIALON Version 1.4
29 Oct 2014 removed AT$UDPONLINE,added AT$TCPCONNECT,AT$UDPCONNECT Version 1.5
T
h
e
S
m
a
r
T
h
e
S
m
a
r
U
s
e
r
G
U
s
e
r
G
Version 1.0
Version 1.1
Version 1.2
Version 1.3
Intercel Pty. Ltd.
A.C.N. 007 077 161
33 Glenvale Crescent
Mulgrave VIC. Australia 3170
Email :
intercel@intercel.com.au
Internet :
www.intercel.com.au
Ph : 61 3 9239 2000 Fax : 61 3 9561 2614
t
S
A
M
3
S
t
S
A
M
3
S
u
i
d
e
u
i
d
e
1

Advertisement

Table of Contents
loading

Summary of Contents for Intercel Smart SAM3S

  • Page 1 Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 Document history 11th Feb 2013: Start Version 1.0 Oct.
  • Page 2: Table Of Contents

    7.1 Power consumption 7.2 Receive sensitivity 7.3 Conducted transmit power tolerances 7.4 Main antenna specifications 7.5 Environmental characteristics 8. Smart SAM3S TCP/IP Operation 8.1 Communication sockets 8.2 TCP/IP AT Commands 8.3 CSD call escape sequence 9. Firmware upgrade 9.1 The 3G module firmware upgrade...
  • Page 3: Introduction

    GSM, GPRS, UMTS and HSPA+ connectivity. The Smart SAM3S is designed for both mobile and fixed M2M applications. It has an RJ45 socket for input voltage and the serial RS232 signals, an FME-male for antenna connection, a SIM holder and an LED indicator.
  • Page 4: Safety Precautions

    This is because the transceiver is designed to use minimum power to connect to the network. The Smart SAM3S modem is approved to use in applications where the antenna is placed more than 21cm from the body.
  • Page 5 It must be placed at an appropriate collection point for the recycling of electrical and electronic equipments. By ensuring the correct disposal of this equipment, it will help the environment and human’s health. The recycling will help to conserve the natural resources. The Smart SAM3S product is RoHS compliant...
  • Page 6: The Packaging Box

    The Data cable is 2m long The Label size is 50mm x 33mm The Power supply is available on request. It is recommended that the Smart SAM3S is powered using a 12Vdc/1A power supply. Antennas are also available on request. Please make sure the correct antenna is used to get optimised...
  • Page 7: The Production Label

    352679010 049570 : Intercel Pty Ltd Made by : ASSSMRTS3S Part number The production part number is located at the back of the Smart SAM3S, which includes: The product model The software Version The Hardware Version The IMEI number The manufacturer...
  • Page 8: Functionality

    6. Functionality General The Smart SAM3S modem consists of an RJ45 socket for serial port and input power, an FME male antenna connector and a SIM holder. The LED indicator, located next to the SIM holder, indicates the Smart SAM3S operating status. It also has a USB port to download firmware.
  • Page 9: The Rj45 Socket

    Input voltage 5Vdc - 32Vdc Data Carrier Detect DTR/RI Data terminal Ready/Ring Indicator Common Ground Serial Data out of the Smart SAM3S Serial Data into the Smart SAM3S Clear to Send Ready to Send 7.1 The FME-Male 50Ω antenna connector The FME male antenna connector is a 50Ω...
  • Page 10: The Data Cable

    The data cable is 2m long. It consists of an RJ45 plug, a DB9-female connector and a 2-wire input power. Signals RJ45 Description Data Carrier Detect Serial Data out of the Smart SAM3S Serial Data into the Smart SAM3S Not used Common Ground Ready to Send...
  • Page 11: Power Consumption

    Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 7.1 Power consumption (TBC) Idle mode <0.225W Sleep mode 0.15W...
  • Page 12: Main Antenna Specifications

    Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 7.4 Main antenna specifications Max cable loss 0.5dBm 50Ω...
  • Page 13: Communication Sockets

    Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 8. THE SAM3S TCP/IP Operation The SAM3S has a MCU (Microcontroller) to control the 3G module PHS8-P, the SAM3S can be operating...
  • Page 14: Tcp/Ip At Commands

    Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 TCP AT Command: Socket connection allows a user from the host computer to send AT commands to the modem and receive its responses, socket will be disconnected after 5 minutes of no activity, and socket also can be used for remote firmware update.
  • Page 15 Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 DATALEN=Serial port data bits 7 or 8 PARITY= NONE or ODD or EVEN SAMMODE=0 for standard modem, 1 for PSD mode, 2 for CSD mode.
  • Page 16 Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 AT$PARAMETERS? $PARAMETERS: APN: telstra.extranet USERNAME: intercel PASSWORD: mach LTCPPORT: 10000 RTCPIP: 203.45.1.236...
  • Page 17 DDNSPASSWORD=DDNS account password DDNSSERVER=DDNS server DDNSSTRING: Only need to change from default in some circumstances with Intercel support DDNSAUTH: Only need to change from default in some circumstances with Intercel support DDNSAGENT: Only need to change from default in some circumstances with Intercel support PDNSIP=Primary DNS, leave blank if not using your own DNS server, not a requirement for DDNS.
  • Page 18 Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 DDNSSERVER: dynupdate.no-ip.com DDNSSTRING: GET /nic/update?hostname=%s&myip=%s HTTP/1.0 DDNSAUTH: Authorization: Basic %s DDNSAGENT: User-Agent: SAM3S/1.0 intercel@intercel.com.au PDNSIP: 8.8.8.8 SDNSIP: 8.8.4.4 DNSTTL: 240 AT$DDNSTEST Use to force a manual updating of IP to the DDNS server, all required parameters must be set beforehand.
  • Page 19 Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 REMOTEIP2= nnn.nnn.nnn.nnn REMOTEIP3= nnn.nnn.nnn.nnn REMOTEIP4= nnn.nnn.nnn.nnn SMSBLOCK=0 or 1 (0 disable, 1 enable remote SMS access from REMOTESMS1-REMOTESMS4)
  • Page 20 Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 REMOTESMS4: DIALBLOCK: 1 REMOTEDIAL1: 0395612959 REMOTEDIAL2: REMOTEDIAL3: REMOTEDIAL4: AT$LOGIN Use to setup login details for remote sending of AT commands, parameters and software updating;...
  • Page 21: Csd Call Escape Sequence

    300s period, modem will not able to decode AT$ commands sending to it over SMS. 8.3 CSD Call Escape Sequence During CSD call to the Smart SAM3S modem, send three consecutive EscEscEsc or hex number sequence 0x1B 0x1B 0x1B to switch the modem between data mode and remote AT commands mode.
  • Page 22: Firmware Upgrade

    Intercel Pty. Ltd. A.C.N. 007 077 161 33 Glenvale Crescent Mulgrave VIC. Australia 3170 Email : intercel@intercel.com.au Internet : www.intercel.com.au Ph : 61 3 9239 2000 Fax : 61 3 9561 2614 9.Firmware upgrade 9.1 Firmware upgrade for the 3G module The module’s firmware can be upgraded over the serial or USB port using the dedicated Upgrade...

Table of Contents