Gas Hook-Up Instructions - Napoleon BIPRO 500 Manual

Hide thumbs Also See for BIPRO 500:
Table of Contents

Advertisement

Available languages

Available languages

6

Gas Hook-Up Instructions

!
WARNING!
EN
serviced by a qualified installer to local codes.
WARNING!
WARNING!
the grill. If the supply pressure is greater, a regulator must be installed.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instructions. A flexible metal connector is included to
simplify the installation of the unit. Connect this flexible metal connector to the flare fitting on the end of
the manifold. Connect the other end of the connector to the gas piping. Ensure that the connector does
not pass through a wall, floor, ceiling or partition, and is protected from damage. Do not use a hose to
connect the unit except to connect the cylinder regulator to the piping system. It must be connected with
rigid pipe, copper tube or an approved flexible metal connector which complies with national and regional
codes.
The installation must comply with national and regional codes. The gas supply pipe must be sufficiently
sized to supply the kW input specified on the rating plate, based on the length of the piping run. If
installing a side burner, a separate line must be branched off to the side burner unit and enter the side
burner opening at the specified location. If the enclosure is to house a propane cylinder, the tank portion
of the enclosure must be ventilated according to local codes, and must not have communication with the
cavity used to enclose the gas grill. A propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed ventilation opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 130 cm
for a cylinder up to 9 kg and 195 cm
2. At least one ventilation opening on the exposed, exterior side of the enclosure located 25.4 mm or less
from the floor level. The opening must have a total free area of more than 65 cm
and 100 cm
floor level.
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
25.4mm
MAXIMUM
www.napoleongrills.com
N415-0378CE-GB-DE DEC 12.18.indd 6
This grill is designed for non-combustible enclosures only, and must be installed and
Cabinet frame, cabinet, and counter top must be made from non-combustible material.
The pressure supplied to the grill must conform to what is listed on the rating plate of
2
for a for a cylinder larger than 9 kg. The upper edge must be no more than 127 mm above the
OPENING
A
127mm
MAXIMUM
864mm
RECOMMENDED
OPENING
B
127mm
MAXIMUM
2
for a cylinder larger than 9 kg.
51mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
CYLINDER SIZE
OPENING A AREA
20 lb (9.1kg)
2
20in
(130cm
30 lb (13.6kg)
2
30in
(195cm
2
for a cylinder up to 9 kg
NON LOCKING DOOR
OPENING B AREA
2
2
2
)
10in
(65cm
)
2
2
2
)
15in
(100cm
)
N415-0378CE-GB-DE DEC 12.18
12/11/2018 10:06:56 AM
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents