Pressure Relief Valve; Replacing The Drive Coupling - Vanair Reliant RS45 Installation, Operation, Maintenance And Parts Manual

45 cfm/ 150 psig hydraulic-driven, open center & closed center. 12v & 24v, (optional) cold-weather, rotary screw compressor
Table of Contents

Advertisement

RELIANT RS45 AIR COMPRESSOR
KEY
A
FUSE, 10A WITH BOOT
B
BREAKER, 40A WITH STUDS & BOTT
IMPORTANT
Reason(s) for shutdown should be
investigated before pressing reset.

5.4.6 PRESSURE RELIEF VALVE

Although the pressure relief valve has a
reset ring at the cap, DO NOT test the
pressure relief valve by pulling on the reset
ring. The pressure relief valve requires no
safety testing. If faulty, replace the valve
(refer to symptoms and recommendations
given in the Troubleshooting Guide in
Section 6).

5.4.7 REPLACING THE DRIVE COUPLING

Before performing maintenance:
Shut down machine, relieve all system
pressure and lock out all power, as per the
Safety Section of this manual.
NOTE THAT THE SYSTEM CAN BE
STARTED REMOTELY:
Always clearly tag the start-up
instrumentation against accidental system
start-ups during maintenance.
VANAIR MANUFACTURING, INC.
(844) VAN-SERV • www.vanair.com
DESCRIPTION
Figure 5-3: Fuse, Circuit Breaker, and Relay Locations
WARNING
090126-OP_r0 (JAN-2018)
A
C
B
KEY
C
RELAY, NO/NC WEATHERPROOF
WITH RESISTOR
With proper care of the machine, the drive
coupling should normally last indefinitely.
However, it may become worn or ruptured
and need to be replaced. To replace the
drive coupling, order replacement element
no. 277764, and follow the procedure below.
Alignment checks should not be necessary,
as the machine is factory-set. However,
when performing a coupling element
replacement, proper sizing and offset
measurements must be properly set and
checked to avoid damage to machine and/or
IMPORTANT
It is important to remember that the drive
coupling contains wear elements that will
eventually fail. Operator must ensure that the
assembly is enclosed to avoid injury in case
TOOLS REQUIRED
TORQUE WRENCH
MEDIUM STRENGTH REMOVEABLE
®
LOCTITE
ALIGNMENT TOOLS (i.e, straight edge, dial indicator, shims, etc).
SECTION 5: MAINTENANCE
DESCRIPTION
NOTE
coupling.
of a failure.
ALLEN SOCKETS
CALIPERS / FEELER
GAUGES
PAGE - 31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents