How to Programme
Digital input function
Select
Reset Counter A
[62]
Counter B (up)
[63]
Counter B (down)
[64]
Reset Counter B
[65]
Sleep Mode
[66]
Reset Maintenance Word
[78]
PTC Card 1
[80]
Lead Pump Start
[120]
Lead Pump Alternation
[121]
Pump 1 Interlock
[130]
Pump 2 Interlock
[131]
Pump 3 Interlock
[132]
5-12 Terminal 27 Digital Input
The parameter contains all options and functions listed in
parameter group 5-1* Digital Inputs except for option [32] Pulse
input.
5-13 Terminal 29 Digital Input
The parameter contains all options and functions listed in
parameter group 5-1* Digital Inputs.
5-14 Terminal 32 Digital Input
The parameter contains all options and functions listed in
parameter group 5-1* Digital Inputs except for option [32] Pulse
input.
5-15 Terminal 33 Digital Input
The parameter contains all options and functions listed in
parameter group 5-1* Digital Inputs.
5-40 Function Relay
Array [8]
(Relay 1 [0], Relay 2 [1]
Option MCB 105: Relay 7 [6], Relay 8 [7] and Relay 9 [8]).
Select options to define the function of the relays.
The selection of each mechanical relay is realised in an array
parameter.
Option:
[0]
No operation
[1]
Control Ready
[2]
Drive ready
[3]
Drive rdy/rem ctrl
[4]
Standby / no warning
[5]
Running
[6]
Running / no warning
[8]
Run on ref/no warn
[9]
Alarm
[10]
Alarm or warning
[11]
At torque limit
[12]
Out of current range
[13]
Below current, low
MG16B202
Operating Instructions
Terminal
5-40 Function Relay
All
Array [8]
29, 33
(Relay 1 [0], Relay 2 [1]
29, 33
Option MCB 105: Relay 7 [6], Relay 8 [7] and Relay 9 [8]).
All
Select options to define the function of the relays.
All
The selection of each mechanical relay is realised in an array
All
parameter.
All
Option:
All
[14]
All
[15]
All
[16]
All
[17]
All
[18]
[19]
[20]
[21]
[25]
[26]
[27]
[28]
[29]
[30]
[33]
[35]
[36]
[37]
[40]
[41]
[42]
[45]
[46]
[47]
[60]
[61]
[62]
[63]
[64]
[65]
Function:
[70]
[71]
[72]
[73]
[74]
[75]
Default setting for relay
[80]
2.
[81]
[82]
[83]
[84]
Default setting for relay
[85]
1.
[160]
[161]
[165]
[166]
Danfoss A/S © Rev. 06/2014 All rights reserved.
Function:
Above current, high
Out of speed range
Below speed, low
Above speed, high
Out of feedb. range
Below feedback, low
Above feedback, high
Thermal warning
Reverse
Bus OK
Torque limit & stop
Brake, no brake war
Brake ready, no fault
Brake fault (IGBT)
Safe stop active
External Interlock
Control word bit 11
Control word bit 12
Out of ref range
Below reference, low
Above ref, high
Bus ctrl.
Bus ctrl, 1 if timeout
Bus ctrl, 0 if timeout
Comparator 0
Comparator 1
Comparator 2
Comparator 3
Comparator 4
Comparator 5
Logic rule 0
Logic rule 1
Logic rule 2
Logic rule 3
Logic rule 4
Logic rule 5
SL digital output A
SL digital output B
SL digital output C
SL digital output D
SL digital output E
SL digital output F
No alarm
Running reverse
Local ref active
Remote ref active