Maintaining the SG6000 appliance

You might need to perform maintenance procedures on the SG6000 appliance. The procedures in this
section assume that the appliance has already been deployed as a Storage Node in a StorageGRID
Webscale grid.
Steps
1.

Upgrading SANtricity OS Software on the E2800 controllers

2.
Replacing an E2800 controller
3.
Replacing hardware components in the E2860 controller shelf
4.
Replacing the SG6000-CN controller
5.
Replacing a power supply in the SG6000-CN controller
6.
Changing the link configuration of the SG6000-CN controller
Upgrading SANtricity OS Software on the E2800 controllers
You might need to upgrade the E-Series SANtricity OS Software on the E2800 controllers, if the
controllers are not functioning optimally.
Before you begin
You have contacted technical support and have obtained SANtricity OS Software and NVSRAM files
that are compatible with your StorageGRID Webscale appliance.
Attention:
Do not upgrade the SANtricity OS Software or NVSRAM in the E2800 controllers
unless directed to do so by technical support. Without the guidance of technical support, your
StorageGRID Webscale appliance could become inoperable. Contact technical support with any
upgrade-related questions.
About this task
Before you can apply a SANtricityOS Software upgrade, you must place the SG6000-CN controller
into maintenance mode, which interrupts the connection to the E2800 controller. Putting a
StorageGRID Webscale appliance into maintenance mode might make the appliance unavailable for
remote access.
Do not upgrade the SANtricity OS Software or NVSRAM in the E2800 controllers on
Attention:
more than one StorageGRID Webscale appliance at a time. Doing so may cause data unavailability,
depending on your deployment model and ILM policies.
Steps
1. If the StorageGRID Webscale appliance is running in a StorageGRID Webscale system, place the
SG6000-CN controller into maintenance mode.
a. From the service laptop, log in to the grid node:
i. Enter the following command:
ii. Enter the password listed in the
iii. Enter the following command to switch to root:
on page 67
on page 73
on page 74
ssh admin@grid_node_IP
Passwords.txt
su -
on page 65
on page 72
on page 76
file.
65

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageGRID Webscale SG6000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Storagegrid webscale sg6060

Table of Contents