4
RADAR FIELD AND AIR PATTERN
1
By turning this screw, the radar
field angle can be adjusted
from -8° to +22°.
The total angle is the sum of the sensor angle and the radar field angle. All detection field dimensions were measured
in optimal conditions and a sensitivity value of 7.
f
6
3
0
f
8 ft
4
8
11.5 ft
12
16 ft
16
20
Sensor angle: 30°
Radar field angle: -8°
Total angle: 22°
f
3
0
6
f
3
0
6
f
f
4
4
8
8
12
12
16
16
20
20
Sensor angle: 30°
Radar field angle: -8°
Total angle: 22°
75.5695.07 IS40 IS40XL 20170313
2
Adjust the field size.
S = 2, L = 7.
3
6
f
f
4
8
12
16
20
Sensor angle: 30°
Radar field angle: 0°
Total angle: 30 °
6
f
3
6
f
3
f
f
8 ft
8 ft
4
4
10 ft
10 ft
11.5 ft
11.5 ft
8
8
12
12
16
16
20
20
Sensor angle: 30°
Radar field angle: 0°
Total angle: 30 °
0-9
p. 6
IS40
6
3
0
3
8 ft
11.5 ft
16 ft
IS40 XL
3
0
6
3
3
0
6
6
3
8 ft
8 ft
10 ft
10 ft
11.5 ft
11.5 ft
3
Choose the right
detection filter for your
application.
6
f
6
f
4
8
12
16
20
11
Sensor angle: 30°
Radar field angle: +11°
Total angle: 41°
6
f
6
f
6
f
f
4
4
8
8
12
12
16
16
20
20
11
Sensor angle: 30°
Radar field angle: +11°
Total angle: 41°
1-6
p. 6
3
0
3
6
8 ft
11.5 ft
16 ft
3
0
6
3
3
0
6
3
8 ft
8 ft
10 ft
10 ft
11.5 ft
11.5 ft
Page 5 of 9