Chicago Electric 92280 Assembly And Operating Instructions Manual page 9

10,000 watt (11,000 peak) generator with 18 hp robin engine
Table of Contents

Advertisement

6.
If you are using an extension cord outdoors, make sure it is marked with the suffix "W-
a" ("W" in Canada) to indicate it is acceptable for outdoor use.
7.
Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified electrician
before using it.
8.
Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.
9.
Extension cords used on the 240 VAC outlet must of sufficient size to carry the
wattage load of the appliance being powered.
RECOMMENDED MINIMUM WIRE
GAUGE fOR ExTENSION CORDS*
(120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
0 – 2.0
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
TABLE A
skU 92280
ExTENSION CORD
LENGTH
18
18
18
18
16
18
18
18
16
14
18
18
16
14
12
18
16
14
12
12
18
14
12
10
14
12
10
-
12
10
-
-
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
For technical questions, please call 1-800-444-3353
Symbology
double insulated
Canadian standards association
Underwriters laboratories, inc.
V~
volts alternating Current
A
amperes
-
no load revolutions per Minute
-
n 0 xxxx/min.
(rPM)
-
Page 9