Manoeuvre Counter Resetting; Troubleshooting Guide; Troubleshooting; Memory Deletion - Nice S-BAR Instructions And Warnings For Installation And Use

Barrier gate operators for all sizes
Table of Contents

Advertisement

7.6 MANOEUVRE COUNTER RESETTING

Once maintenance has been performed on the system, the ma-
noeuvre counter must be reset.
40
To do this:
press and hold the
1.
o
release the
button when LED "L1" starts flashing
2.
o
press the
or
button to shift the flashing LED to "L7",
3.
p
q
that is, the "entry LED" for the "Maintenance notice" pa-
rameter
press and hold the
4.
o
– wait roughly 3 seconds until the LED representing the
current level of the "Maintenance notice" parameter
lights up
– press and hold for at least 5 seconds the
buttons then release them. The LED corresponding to
the selected level will emit a series of fast flashes to
signal that the manoeuvre counter has been reset
release the
button
5.
o
8

TROUBLESHOOTING...

(troubleshooting guide)

8
TROUBLESHOOTING GUIDE
8.1 TROUBLESHOOTING
The table below contains useful instructions to resolve any malfunctions or errors that may occur during installation or in case of a
fault.
TROUBLESHOOTING
Problems
The radio transmitter does not
control the gate and the LED on the
transmitter does not light up
The radio transmitter does not
control the gate but the LED on the
transmitter lights up
No manoeuvre starts and the
"BlueBUS" LED does not flash
No manoeuvre starts and the warning
light is off
No manoeuvre starts and the warning
light flashes a few times
The manoeuvre starts but is
immediately followed by a reverse run
L1
L7
button until LED "L1" starts flashing
button. With the
button pressed:
o
p
Recommended checks
Check whether the transmitter batteries are exhausted and replace them if necessary.
Check whether the transmitter has been memorised correctly in the radio receiver.
Check that the gearmotor is being powered with the mains voltage
Check whether fuses F1 and F2 are blown; if they are, identify the cause of the failure then
replace the fuses with others having the same current rating and characteristics, according
to that indicated in "Table 9".
Check that the command is actually received. If it reaches the Step-by-Step input, the
corresponding "Sbs" LED must light up; if instead the radio transmitter is used, the
"BlueBus" LED must emit two fast flashes.
Count the number of flashes and check the corresponding value in "Table 7".
The selected force value may be too low to move the type of gate. Check whether there are
any obstacles and, if necessary, select a higher force.
Check whether a safety device connected to the Stop input has tripped.

7.7 MEMORY DELETION

m
The procedure described below restores the con-
trol unit's default settings. All the custom settings
will be lost.
41
To delete the control unit's memory and restore all the default
settings, proceed as described below:
1.
press and hold the
ming LEDs "L1-L8" light up (after roughly 3 seconds)
release the buttons.
2.
LEDs "L1" and "L2" will start flashing at the end of the proce-
dure.
l
With this procedure it is possible to also delete any
and
q
errors left in the memory.
l
This procedure does not cancel the parameter rel-
ative to the motor's rotation direction and the num-
ber of manoeuvres executed.
L1 ... L8
and
buttons until the program-
p
q
Table 8
ENGLISH – 23

Advertisement

Table of Contents
loading

Table of Contents