7.2 LEVEL 1 PROGRAMMING (ON-OFF)

All the Level 1 functions are factory-set to "OFF" with the exception of parameter "L5" and can be modified at any time. To check
the various functions, refer to "Table 5". Take care during modification procedures, as there is a maximum time interval of 10 sec-
onds between pressing of different buttons; otherwise the procedure terminates automatically and stores the changes made up to
that time.

7.2.1 Level 1 programming procedure

m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 1 programming:
press and hold the
1.
release the
button when LED "L1" starts flashing
2.
o
press the
or
button to move the flashing LED to the LED associated with the function to be modified
3.
p
q
press the
button to change the status of the function:
4.
o
– short flash = OFF
– long flash = ON
5.
wait 10 seconds (maximum time) to exit the programming mode.
l
To set other functions to "ON" or "OFF", while the procedure is running, repeat points 2 and 3 during the phase
itself.
LEVEL 1 FUNCTIONS (ON-OFF)
LED
Function
L1
Automatic closing
L2
Close after photo
L3
Always Close
L4
Stand-by
L5
Long slowdown
L6
Pre-flashing
L7
Sensitivity
Motor rotation
L8
direction
l
During normal operation, LEDs "L1 ... L8" are on/off depending on the status of the respective function; for
example, "L1" is lit when the "Automatic Closing" function is enabled.
l
During the manoeuvre, LEDs "L1 ... L8" flash to signal the force required to move the boom at that time. If "L1"
flashes, the force required is low and so forth, until LED "L8" flashes to signal the maximum force.
button until LED "L1" starts flashing
o
Description
Function ENABLED: after an opening manoeuvre there is a pause (equal to the set pause time), after
which the control unit automatically starts a closing manoeuvre. The pause time is set by default to 30
seconds.
Function NOT ENABLED: the system works in "semi-automatic" mode.
Function ENABLED: the behaviour changes depending on whether the "Automatic Closing" function is
enabled or not.
When "Automatic Closing" is disabled: the boom gate always reaches the fully open position (even if the
Photo disengages first). When Photo disengages, automatic closing is triggered with a 5-second pause.
When "Automatic Closing" is enabled: the opening manoeuvre stops immediately after the photocells have
disengaged. After 5 seconds, the gate will start closing automatically.
The "Close After Photo" function is always disabled in manoeuvres interrupted by a Stop command.
Function DISABLED: the pause time is that which has been programmed or automatic re-closing will not
take place if the function is disabled.
Function ENABLED: in the event of a blackout, even of short duration, if the control unit detects that the
gate is open once the electricity is restored, it automatically starts a closing manoeuvre, preceded by a
3-second pre-flashing sequence.
Function DISABLED: when the electricity is restored, the gate remains in the same position.
Function ENABLED: 1 minute after the completion of the manoeuvre, the control unit switches off the
BlueBUS output (and, therefore, the devices) and all LEDs, with the exception of the BlueBUS LED, which
flashes more slowly. When the control unit receives a command, it restores full operation.
Function DISABLED: there will be no reduction in consumption.
This function is useful, in particular, during operation with the back-up battery.
Function ENABLED: allows for doubling the space from which the slowdown starts, during both the
opening and closing manoeuvres.
Function DISABLED: short slowdown.
Function ENABLED: a 3-second pause can be added between the switching on of the warning light and
the start of the manoeuvre, to warn the user in advance of a potentially dangerous situation.
Function DISABLED: the signalling of the warning light coincides with the start of the manoeuvre.
Function ENABLED: allows for considerably increasing the motor's sensitivity in detecting obstacles. If
used to aid impact force detection, the "Speed" and "Motor force" parameters in the Level 2 menu must
also be adjusted.
Function ENABLED: allows for inverting the motor's rotation direction in order to install the barrier to the
right.
Function DISABLED: the factory setting, with the barrier closing towards the left.
WARNING: when this function is enabled, the "Opening" and "Closing" positions must be learned (see the
"Learning of the mechanical stop positions" paragraph).
Table 5