Further Details (Accessories); Modifying The Stop Input Configuration; Connecting An Sm-Type Radio Receiver - Nice S-BAR Instructions And Warnings For Installation And Use

Barrier gate operators for all sizes
Table of Contents

Advertisement

9
FURTHER INFORMATION
(Accessories)
9

FURTHER DETAILS (Accessories)

9.1 MODIFYING THE STOP INPUT
CONFIGURATION
STOP is the input that causes immediate stoppage of the ma-
noeuvre followed by its brief reversal. Devices with output fea-
turing normally open "NO" and normally closed "NC" contacts,
as well as devices with 8.2 kΩ fixed resistor output, such as
sensitive edges, can be connected to this input.
As with the BlueBUS, the control unit recognises the type of
device connected to the STOP input during the learning phase
(see the "Device learning" paragraph); subsequently the con-
trol unit gives a STOP command when it detects a variation with
respect to the recognised status.
Multiple devices, even of different types, can be connected to
the STOP input if suitable arrangements are made:
– Any number of NO devices can be connected to each other
in parallel.
– Any number of NC devices can be connected to each other
in series.
– Two devices with 8.2 kΩ fixed resistor output can be connect-
ed in parallel; if there are more than 2 devices then they must
all be connected in cascade, with a single 8.2 kΩ terminating
resistor.
– It is possible to combine two NO and NC contacts by placing
them in parallel, while also mounting a 8.2 kΩ resistor in series
with the NC contact (this also allows for combining 3 devices:
NA, NC and 8.2 kΩ).
a
If the STOP input is used to connect devices with
safety functions, only those devices with 8.2 kΩ
fixed resistor guarantee Category 3 safety against
faults in accordance with the EN 13849-1 standard.

9.2 CONNECTING AN SM-TYPE RADIO RECEIVER

The control unit has a slot for mounting radio receivers with SM
connector (optional accessories) belonging to the SMXI, OXI,
etc. families, which can be used to remotely control the control
unit through transmitters that intervene on the unit's inputs.
f
Before installing a receiver, disconnect the power
supply to the control unit.
To install a receiver ("Figure 45"):
insert the receiver (A) in the appropriate slot (B) on the
1.
control unit's electronic board.
45
B
The association between the radio receiver output and the com-
mand executed by the motor is shown in "Table 13":
SMXI / SMXIS
Receiver output
Output No. 1
Output No. 2
Output No. 3
Output No. 4
If the OXI radio receiver used in "EXTENDED MODE" is installed,
it may send the commands shown in "Table 14".
OXI / OXIFM /OXIT / OXITFM IN MODE 2 EXTENDED
No.
Command
1
Step-by-Step
2
Partial opening
3
Open
4
Close
5
Stop
Condominium
6
Step-by-Step
High priority Step-
7
by-Step
8
Unlock and Open
9
Unlock and Close
Opens and locks
10
the automation
Closes and locks
11
the automation
12
Lock automation
Release
13
automation
A
On Timer
14
Courtesy light
On-Off
15
Courtesy light
Command
"Step-by-Step"
"Partial opening"
"Open"
"Close"
Description
"SbS" (Step-by-Step) command
"Partial opening" command
"Open" command
"Close" command
Stops the manoeuvre
Command in condominium mode
Commands also with the automation
locked or the commands enabled
Unlocks the locked automation and
carries out an opening manoeuvre
Unlocks the locked automation and
carries out a closing manoeuvre
Triggers an opening manoeuvre
and, once this terminates, locks the
automation; the control unit will not
accept any command other than
"High priority Step-by-Step" and
automation "Unlock", or (only from
Oview) the following commands:
"Unlock and close" and "Unlock and
open"
Triggers a closing manoeuvre and,
once this terminates, locks the
automation; the control unit will not
accept any command other than
"High priority Step-by-Step" and
automation "Unlock", or (only from
Oview) the following commands:
"Unlock and close" and "Unlock and
open"
Triggers the stoppage of the
manoeuvre and locks the
automation; the control unit will not
accept any command other than
"High priority Step-by-Step" and
automation "Unlock", or (only from
Oview) the following commands:
"Unlock and close" and "Unlock and
open"
Triggers unlocking of the automation
and restores normal operation
The courtesy light output switches on
with timer-based switching off
The courtesy light output switches on
and off in Step-by-step mode
ENGLISH – 27
Table 13
Table 14

Advertisement

Table of Contents
loading

Table of Contents