Level 2 Programming (Adjustable Parameters); Level 2 Programming Procedure - Nice S-BAR Instructions And Warnings For Installation And Use

Barrier gate operators for all sizes
Table of Contents

Advertisement

l
Please note that there is no relation between the force level indicated by the LEDs during the movement (which
is an absolute value) and the level indicated by the LEDs during the force (which is a relative value) program-
ming phase. See LEDs "L5" and "L6" in "Table 6".

7.3 LEVEL 2 PROGRAMMING (ADJUSTABLE PARAMETERS)

All the Level 2 parameters are factory-set as highlighted in "GREY" in "Table 6" and can be modified at any time. The parameters
can be set to a scale of 1 to 8. The check the value corresponding to each LED, refer to "Table 6".

7.3.1 Level 2 programming procedure

m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 2 programming:
1.
press and hold the
release the
button when LED "L1" starts flashing
2.
o
3.
press the
or
button to move the flashing LED to the "entry LED" associated with the parameter to be modified
p
q
press and hold the
4.
– wait roughly 3 seconds, until the LED representing the current level of the parameter to be modified lights up
– press the
or
p
q
release the
button
5.
o
wait 10 seconds (maximum time) to exit the programming mode.
6.
l
To set multiple parameters during the procedure's execution, repeat the operations from point 2 to point 4 dur-
ing the phase itself.
LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry LED
Parameter
L1*
Pause Time
Step-by-Step
L2**
function
L3*
Motor speed
L4**
FLASH output
20 – ENGLISH
button until LED "L1" starts flashing
o
button. With the
button pressed:
o
o
button to shift the LED associated with the parameter's value
LED (level)
Set value
L1
5 seconds
L2
10 seconds
L3
20 seconds
L4
40 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
200 seconds
L1
Open - Stop - Close - Stop
L2
Open - Stop - Close - Open
L3
Open - Close - Open - Close
L4
Condominium (more than 2 sec triggers "Stop")
Condominium 2 (less than 2 sec triggers
L5
"Partial Open")
L6
Step-by-Step 2
L7
Hold-to-run
Opening in "semi-automatic" mode, closing in
L8
"hold-to-run" mode
L1
Speed 1 (30% - slow)
L2
Speed 2 (47%)
L3
Speed 3 (65%)
L4
Speed 4 (82%)
L5
Speed 5 (100% - fast)
L6
Open V3, close V2
L7
Open V4, close V3
L8
Open V5, close V4
L1
Gate open indicator
L2
Enabled if boom is closed
L3
Enabled if boom is open
L4
Warning light
L5
Boom light warning light
L6
Electric lock
L7
Suction cup
L8
Maintenance indicator
Description
Adjusts the pause time, in other words,
the time before automatic re-closure.
It is only effective if the "Automatic
Closing" function is enabled.
Controls the sequence of controls
associated with the Sbs input or the 1st
radio command.
Adjusts the motor speed during normal
manoeuvres.
Selects the device connected to the
FLASH output.
Table 6

Advertisement

Table of Contents
loading

Table of Contents