Danfoss VLT MCB 150 Operating Instructions Manual page 74

Hide thumbs Also See for VLT MCB 150:
Table of Contents

Advertisement

Technical Specifications
9.5 Safety Characteristic Data
European
directives
Safety
standards
Safety
function
9
9
Safety
performance
Table 9.1 Safety Characteristic Data
The safety-related characteristic data are valid for all safety
functions.
All units used within a safety function must be considered
when calculating the safety characteristic data.
72
Machinery
EN ISO 13849-1
Directive
EN IEC 62061
(2006/42/EC)
EN IEC 61800-5-2
EN 50011
EMC Directive
EN 61000-6-3
(2004/108/EC)
EN 61800-3
Low Voltage
Directive
EN 50178
(2006/95/EC)
EN 61800-5-1
EN ISO 13849-1
Safety of
IEC 62061
Machinery
IEC 60204-1
Functional
IEC 61508-1 to -7
Safety
IEC 61800-5-2
IEC 61800-5-2
Safe Torque Off
(STO)
Safe Stop 1
(SS1)
Safely Limited
Speed (SLS)
Safety Integrity
SIL 2
Level
SIL CL2
HFT (IEC 61508) Hardware Fault Tolerance = 1
Subsystem
Classification
Type B
Probability of
Dangerous
Failure per
Hour
PFH: 1,52 e-8
Probability of
Dangerous
Failure on
Demand
PFD: 1,33 e-3
Category
Cat 3
Performance
Level
PL d (cat 3)
Mean Time to
Dangerous
Failure of each
Channel
MTTFd: 245 years (High)
Average
Diagnostic
Coverage
DC
: 86% (Low)
ave
Safe Failure
Fraction
SFF: 90%
Proof Test
Interval
20 Years
Danfoss A/S © Rev. 2014-02-11 All rights reserved.
Operating Instructions
IEC 60204-1
Stop Category
0
Stop Category
1
MG34W302

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt mcb 151

Table of Contents