Service and Repair
Message
0 RPM
Safety Password
Please enter the safety
Password
0
0000000
0 RPM
Pa
0-
Password accepted
[0
7
7
0 RPM
Pa
0-
Password rejected
[0
0 RPM
SO Data Con rmation
Are you sure that you want
to overwrite the safety
parameters including the
level 1 password?
0 RPM
SO Data Con rmation
Press [OK] to con rm
(commissioning test must be
performed) or [CANCEL] to
abort
Status
0 RPM
None
SO Custom. completed
SO RESET required!
!Safe Stop [W68]
O Remote SO Req.RESET
Status
0 RPM
SO Custom. aborted
SO RESET required!
!Safe Stop [W68]
O Remote SO Req.RESET
Table 7.2 Mismatch between Safety Parameters in the safety Option and the Frequency Converter
50
None
1(1)
If selecting [VLT:...] and the password protection in 0-69 Password Protection of Safety Parameters is
enabled, enter the correct LCP-copy/parameter mismatch password (0-68 Safety Parameters Password).
None
1(1)
If the entered password is correct, this overlay message is shown for some seconds.
([1] Enabled)
None
1(1)
If the entered password is wrong, this overlay message is shown for some seconds. Then the password
can be entered again.
([1] Enabled)
0.00A
!1(1)
Decision box for continuing overwriting the existing data or to abort the procedure.
0.00A
!1(1)
!1(1)
0.00KW
Press [OK] to complete the customisation of the safety option. A reset is required to finalise this
procedure.
!1(1)
None
0.00KW
Press [Cancel] to abort the customisation of the safety option. A reset is required to finalise this
procedure.
Danfoss A/S © Rev. 2014-02-11 All rights reserved.
Operating Instructions
Description
MG34W302