Optional Settings - DSC PowerSeries Neo Installation Instructions Manual

Hide thumbs Also See for PowerSeries Neo:
Table of Contents

Advertisement

Available languages

Available languages

1.
Select Options, Access Codes [enter Master code].
2.
Select a user to delete.
3.
Select Prox Tag Prog then delete.
Function Key Assignment
The HS2TCHP has 7 buttons on the Home screen, four of them programmable by the
installer. Function key 2 must always be set to "Away Armed."
To program function keys 1,3,4,5:
1.
On the virtual keypad, press [*][8][Installer Code].
2.
Enter [861]-[876] to program keypads 1-16 respectively.
3.
Enter [001-[005] for function keys 1-5 or use the [<][>] keys and press [*].
4.
Enter a 2-digit number to assign a function key operation - [00]-[68]. See Available
Function Key Options below.
5.
Repeat from step 3 until function keys 1, 3, 4, 5 are programmed.
To program function key 6:
1.
Press Options, Installer Menu [Installer Code], Keypad Programming then Home
Functions.
2.
To display the Photo button on the Home page, press Photos. To display the
Keypad Mode button on the Home page, press Keypad Mode.
Available Function Key Options
Refer to your system installation manual for a complete list.
[00] Null
[02] Instant Stay Arm
[04] Away Arm
[05] [*][9] No-entry Arm
[07] [*][6][---][04] System Test
[09] Night Arm
[13] Global Away Arm
[14] Global Disarming
[17] Arm Interior
[21] [*][7][1] Command Output 1 [22] [*][7][2] Command Output 2
[23] [*][7][3] Command Output 3 [24] [*][7][4] Command Output 4 [29] Bypass Group Recall
[31] Local PGM Activate
[32] Bypass Mode
[34] User Programming
[35] User Functions
[39] Trouble Display
[40] Alarm Memory
Programming Labels
1.
From the HS2TCHP keypad, press Options, press Installer Menu [Installer Code],
then press Label Programming.

Optional Settings

The following settings are available through the Options menu.
Enable/Disable Fire, Medical, Panic Buttons
Extra Power Option
The Extra Power option will increase the brightness of the display. To enable the option:
Note: Enabling the Extra Power option will put the keypad into a higher current mode and the
keypad will draw 300 mA. In Extra Power mode, reduce the maximum wire length from 101 m (332
ft.) to 54 m (177 ft.)
Change the Background Image
[03] Stay Arm
[06] [*][4] Chime ON/OFF
[12] Global Stay Arm
[16] [*][0] Quick Exit
Dark Text Enable/Disable
[33] Bypass Recall
[37] Time/ Date Program
[61] - [68] Partition Select 1 - 8
2.
From the Label screen, press the item that you want to label (e.g., zones, partitions,
etc.).
3.
Enter the label name for the selected item.
4.
Press Save when complete.
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then
Options.
2.
Enable/disable the desired Fire, Medical and Panic buttons.
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then
Options.
2.
Enable or disable the extra power option.
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then Back-
ground Image.
2.
Select image to use from SD card as background image.
3.
To exit, press the Back or the Home button.
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then
Options.
2.
Select the desired text color by enabling or disabling Dark Text. (This will make
the text white).