Optional Settings; Keypad Programming - DSC PowerSeries Neo Installation Instructions Manual

Hide thumbs Also See for PowerSeries Neo:
Table of Contents

Advertisement

Available languages

Available languages

Available Function Key Options
Refer to your system installation manual for a complete list.
[00] Null
[02] Instant Stay Arm
[04] Away Arm
[05] [*][9] No-entry Arm
[07] [*][6][---][04] System Test
[09] Night Arm
[13] Global Away Arm
[14] Global Disarming
[17] Arm Interior
[21] [*][7][1] Command Output 1 [22] [*][7][2] Command Output 2
[23] [*][7][3] Command Output 3 [24] [*][7][4] Command Output 4 [29] Bypass Group Recall
[31] Local PGM Activate
[32] Bypass Mode
[34] User Programming
[35] User Functions
[39] Trouble Display
[40] Alarm Memory
Programming Labels
1.
From the HS2TCHP keypad, press Options, press Installer Menu [Installer Code],
then press Label Programming.
2.
From the Label screen, press the item that you want to label (e.g., zones, partitions,
etc.).
3.
Enter the label name for the selected item.
4.
Press Save when complete.

Optional Settings

The following settings are available through the Options menu.
Enable/Disable Fire, Medical, Panic Buttons
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then
Options.
2.
Enable/disable the desired Fire, Medical and Panic buttons.
Extra Power Option
The Extra Power option will increase the brightness of the display. To enable the option:
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then
Options.
2.
Enable or disable the extra power option.
Note: Enabling the Extra Power option will put the keypad into a higher current mode and the
keypad will draw 300 mA. In Extra Power mode, reduce the maximum wire length from 101 m (332
ft.) to 54 m (177 ft.)
Change the Background Image
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then Back-
ground Image.
Dark Text Enable/Disable
[03] Stay Arm
[06] [*][4] Chime ON/OFF
[12] Global Stay Arm
[16] [*][0] Quick Exit
Note: This feature affects only the text on the Classic (square) button home page.
[33] Bypass Recall
Perform a Firmware Upgrade
[37] Time/ Date Program
[61] - [68] Partition Select 1 - 8

Keypad Programming

To enter keypad programming:
Once a keypad is selected, the following programming options are available:
[000] Keypad Partition Mask
Valid entries are 01-08. Global keypad mode not supported
[011] Keypad Input/Output Programming
Zone or PGM Number
[012] Local PGM Output Pulse Activation Time
I___I___I
[021] First Keypad Options
Default Value Option
ON
ON
ON
ON
2.
Select image to use from SD card as background image.
3.
To exit, press the Back or the Home button.
1.
Press Options, Installer Menu [Installer Code], Keypad Programming, then
Options.
2.
Select the desired text color by enabling or disabling Dark Text. (This will make
the text white).
1.
Insert an SD card in the HS2TCHP with the new firmware.
2.
Press Options, Installer Menu [Installer Code], Keypad Programming, then Firm-
ware Upgrade.
3.
Select OK to perform a firmware upgrade (if a new firmware version is available).
1.
Press Options then Keypad Mode. The virtual keypad is displayed.
2.
Press [*][8][Installer Code].
3.
Enter one of the following keypad programming sections:
[860] Keypad Slot Number. This section is for display only.
l
[861]-[876] to program keypads 1-16 respectively.
l
Default 000
Minutes (00-99)
I__I
1
Fire Key Enabled
I__I
2
Medical Key Enabled
I__I
3
Panic Key Enabled
Display Access Code When Pro-
I__I
4
gramming
I___I___I___I
I___I___I
Seconds (00-99)
ON
Off
Fire Key Disabled
Medical Key Disabled
Panic Key Disabled
Display Xs When Programming
Access Codes
|___|___|

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hs2tchp