13.2
System Control Specifications
Set point operating range:
Ambient temperature operating range
displayed:
Sensor accuracy:
Low voltage limit 230 V units:
Low voltage processor reset:
Line voltage:
Frequency:
Fan output (max.):
Valve output:
Heater output (max.):
Pump output:
Compressor output:
Minimum operating temperature:
Maximum ambient operating temperature:
Maximum Rh conditions:
Display power consumption
13.3
System Inputs
Ambient or inside air temperature:
High pressure switch, HPF:
Low pressure switch, LPF
(Not used in MCST):
Alternate inside air temperature sensor:
Outside air temperature sensor (optional):
EN
18.3 °C to 29.4 °C (65 °F to 85 °F)
–15 °C to 65.6 °C (5 °F to 150 °F)
±1.1 °C at 25 °C (± 2 °F at 77 °F)
175 Vw
50 Vw
230 Vw
50 Hz
6 A at 230 Vw
0.25 A at 230 Vw
20 A at 230 Vw
1/2 HP at 230 Vw
2 HP at 230 Vw
–17.8 °C (0 °F)
82.2 °C (180 °F)
99 % Non Condensing
< 5 W
1
1
1
1
1