Dometic MCS T6 Operating Manual page 18

Marine air conditioner
Hide thumbs Also See for MCS T6:
Table of Contents

Advertisement

Available languages

Available languages

Programming
Program
Description
number
P-9
High Water Temperature
Limit (°F)
P-10
Display Brightness
Control
P-11
º
Display
F or
P-12
Cycle Pump With
Compressor or
Continuous Pump
P-13
Reverse Fan Speeds Dur-
ing Heating Mode
P-14
Continuous Fan or Cycle
Fan with Compressor
P-15
Reverse Cycle Heating or
Electric Heat Only Option
Installed (cooling only
units)
P-16
Fan Motor type selection
Shaded Pole or Split
Capacitor.
P-17
Reset Memorized
Programming Defaults
P-18
Reserved for Future
Option
P-19
Reserved for Future
Option
P-20
Filter Threshold
(x10 hours)
P-21
Current Filter Time
(x10 hours)
P-22
Voltage Calibration (Volts)
18
Default
OFF
º
C
OFF
con
x10 Hours Using
Current Filter
AC Voltage
MCS T6, MCS T12, MCS T16
Range
100 – 150
9
4 = Low
13 = Maximum
F
F = Fahrenheit displayed
C = Celsius displayed
OFF = Cycle with compressor
On = Continuous pump
rEF
nor = Normal fan operation
rEF = Reversed fan in heating
CYC = Cycle fan with compressor
con = Continuous fan operation
nor
nor = Reverse cycle heating
ELE = Electric heater installed
SC
SP = Shaded pole fan motor
SC = Split capacitor fan motor
nor
rSt = Reset defaults
nor = Normal
00
00 – 250
EN