1.Important Safety tips The meaning of this user manual is shown below. Please avoid such operations, in case of any safety and health risks. Such instructions have to be followed, for safety and health concerns. 1.1 Precautions For household use only For indoor use only;...
Page 4
Please wipe the machine with a soft Do not operate the machine with cloth, instead of wax, diluent or wet hands or in a humid irritant detergent. environment. For your health,never drink Clean the filter once every two condensed water discharged weeks from the machine.
Page 5
1.2 Safety Warnings Damaged power cord or plug Never damage the power cord, or shall not be used. Never plug to use unlicensed power cord. Make a loose socket. sure voltage is right. A grounded outlet is suggested for Do not modify or extend the power the machine.
Page 6
Please turn off the machine before Never control on/off status by unplugging. directly plugging/unplugging. Keep away from heat sources or Never overload the socket. direct sunlight exposure. In case of electric shock, never If there is any actue noise, smell or damage the power cord by placing smoke, turn off and unplug for heavy objects on it.
Page 7
Keep electrical parts away from Never insert fingers or any hard objects into the louver. water. If water enters, turn off and unplug in Please turn off and unplug before time; and call for check and repair from wiping, cleaning or replacing a professional serviceman.
Page 8
1.3 Tips For a proper work of compressor, For a proper ventilation, keep the place the machine vertically on an machine at least 50cm from objects even ground. nearby. Keep the appliance from spraying Never use the appliance near gasoline or other flammable objects. agent or any solvent,or plastics may deform and electrical parts may even be damaged.
3. Product Operation 3.1 Place and Install Place Best Install Installatio Place the machine on the horizontal floor near the window. For proper ventilation and best machine performance, keep the appliance at least 50cm from objects nearby. 50cm Install Air Exhaust Duct Assembly Flat nozzle Air exhaust duct Connector...
Page 12
Step 1: Screw-fixture type 1.Measure window size; 2.Adjust Length of the plate according to window size; 3. Fix the plate with a screw Fix the screw Firmly Clip-fixture Type 1.Measure window size; 2.Adjust Length of the plate according to window size; 3.Lock the plate Step 2: Fix the plate to window...
Page 13
Small Notch screw First Insert Step 4: Insert the exhaust pipe assembly (exhaust port end) into the window seal panel assembly and screw it up. Impression Drawing of Completion...
Page 14
Incorrect installation It‟s important to keep the exhaust duct smooth. Incorrect installation will affect work of the A/C. Prevent the exhaust duct from sharp bending. Ensure air can flow smoothly in the duct. Warning The exhaust duct is designed especially for this model. Don‟t replace or lengthen it; otherwise, it will result in failure.
Page 15
Warning: Never use leaked batteries. Chemicals in batteries could result in such health hazards as burns. If liquid in batteries splashes to skin or clothes, please wash with clean water in time. If batteries are swallowed, please rinse mouth immediately with clean water and then go to the doctor.
Page 16
How to Operation Cooling Mode Under cooling mode, cooling indicator will light on. Temperature Setting is from 16℃ to 30℃. Press Fan Speed Button to choose from low/ high fan speed. Fan Mode Under Fan mode, indicator will be on. Press Fan Speed Button to choose from low/ high fan speed.
Timer Mode In standby mode, press Timer button to set ON time. A range of 0 to 24 Hours could be set with UP/DOWN button. Timer indicator will light up in this mode. Under running state,press Timer button to set OFF time. A range of 0 to 24 Hours could be set with UP/DOWN button.
Page 18
Filter needs to be cleaned once every two weeks. If air quality indoor is poor, it has to be washed more often, or performance of the appliance would be lowered due to blocked filter screen. Please follow below instructions for cleaning: Take off air-inlet grille as indicated in the photo;...
Page 19
4.3 Seasonal Maintenance If the appliance will not be use for a long time, please maintain by following below steps: Pull out water plug for drainage. Run in Fan mode for at least 2 hours to dry internal parts. Turn off and unplug. Clean the filter and reinstall.
5. Common Failures and Diagnosis 5.1 Intelligent Error Detection Error-detecting code Multi-functional defection Error of the coil‟s temperature sensor Error of indoor temperature sensor Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature excesses 8 ℃ ,the protection is released and previous working state i s recovered.
Page 40
Dometic (Pty) Ltd. Dometic Branch Office Belgium MEXICO Regional Office Zincstraat 3 Dometic Mx, S. de R. L. de C. V. South Africa & Sub-Saharan Africa B-1500 Halle Circuito Médicos No. 6 Local 1 Unit 6-7 on Mastiff Linbro Park ...
Need help?
Do you have a question about the MX 900 and is the answer not in the manual?
Questions and answers