Download Print this page

Technical Specifications - jablotron JA-80Y Manual

Gsm communicator

Advertisement

• A service technician needs only one set of login details to access
various installations. After the first system has been registered, the
installer can add (or remove) other installations to(or from) his/her
GSMLink account.
• there is a demo version of remote access on
• using
www.GSMLink.cz
is free of charge
7.6.
A complete list of CID reports to ARCs
A report to an ARC consists of: installation ID, event code, subsystem
number and the number of the source (device or code). In IP CID and
SMS CID, in addition to this, a time stamp is also sent as follows.
List of the CID reports
CID code
1130 / 3130
Intruder alarm – instant / restored
1134 / 3134
Intruder alarm – delayed / restored
1110 / 3110
Fire alarm / restored
1120 / 3120
Panic alarm / restored
1461 / 3461
Number of incorrect code-entries exceeded
alarm / restored
1140 / 3140
Alarm triggered during control panel power-up /
restored
1137 / 3137
Tamper alarm / no tampering
1144 / 3144
Device tamper alarm / no tampering
1406
Alarm cancelled by user
1401 / 3401
Unsetting / setting
3402
Partial setting
3408
Codeless complete setting
1354 / 3354
External communication fault / restored
1300 / 3300
Fault (except device) / all faults restored
1330 / 3330
Device fault / all faults restored
1301 / 3301
Mains dropout longer than 30 minutes /
restored
1302 / 3302
Battery fault (except devices) / all battery faults
restored
1384 / 3384
Device battery fault / all battery faults restored
1306 / 3306
Switching to Service Mode / Leaving Service
mode
1661 / 3661
PGX ON/OFF
1662 / 3662
PGY ON/OFF
1355
Radio communication jamming present
1350 / 3350
Internal communication fault / restored
1602
Communication test
1138
Unconfirmed alarm
1351
Communication fault to ARC1
1393
Annual check request
1551 / 3551
Communicator blocked / restored
List of source numbers
Source
Source
number
701
Control panel
731
Communicator
741
Wired keypad
001 - 050
Devices 01 - 50
500
Master code
599
Service code
501 - 550
Codes 01 - 50
Subsystem: 01 in all reports
In a split system, for setting and unsetting: 02 = A, 03 = B
For partial setting: 02 = A, 03 = AB
The JA-80Y GSM communicator
www.GSMLink.cz
Event
ec
1 / 9
2 / 9
3 / 9
4 / 9
5 / 9
6 / 9
7 / 8
7 / 8
10
12 / 11
13
14
15 / 16
17 / 18
17 / 18
19, 20 / 21
22 / 23
22 / 23
24 / 25
26
27
28
29 / 30
31
32
to ARC2 if
backups
17
31 only in
IP CID

8. Technical specifications

Power
Stand-by consumption
about 35 mA (depends on the GSM signal)
Max. consumption (during communication)
GSM band
RF output power
AUX output
Complies with
EN 50131-1, EN 50136-2-1, as:
ATS4, ATS 5 if CID protocol is used and the repeating period is set to zero
(sequence 06a0)
Security grade
Operating environment ( –10 to 40°C)
Safety
EMC
Radio transmissions
CLIP protocol (caller ID + SMS)
Can be operated according to:
Jablotron Ltd. hereby declares that the JA-80Y is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC. The original of the conformity assessment can be found
at www.jablotron.com, - Technical Support section
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use.
- 12 -
12V DC (from the control panel)
E-GSM / GPRS 900/1800MHz
2 W for GSM900, 1 W for GSM1800
dry NC contact, max. 60 VDC / 100 mA
EN 60950-1
ETSI EN 301489-1, ETSI EN 301489-7
EN 55022, EN 50130-4
ETSI EN 301419-1 and EN 301511
ETSI EN 300 089 V3.1.1(2000-12)
ERC/DEC 98(20,21)
MFJ55304
1 A
2
class II

Advertisement