JA-190X Telephone PSTN communication module
Detection of dial tone:
Enabled*: The communicator starts dialling a preset tel. number
after the dial tone is detected. If a standard dial tone
is not detected, the communicator stops its activity
and records the message that hasn't been delivered
in the event log.
Disabled: Dials the number immediately when the telephone line
is picked up by the communicator. This option is
recommended if a standard telephone line is not
used or the usual dial tone is not detected.
Detection of busy tone:
Enabled*: The communicator detects a busy tone. When the
communicator detects a busy tone, it hangs up and
records this event in the history.
Disabled: the communicator does not detect a busy tone.
Control of phone line:
The communicator detects the voltage on the telephone line and
also its interruption. When the voltage drops down or the
telephone line is disconnected, then this status is indicated by a
yellow LED.
Enabled *: If the telephone line voltage is interrupted for more
than 30 minutes, a fault is triggered.
Disabled: The telephone line status is not checked. This setting
does not comply with EN 50131-1
Simulated telephone line:
This parameter is meant for the situation when the dialler is
connected to a non-standard telephone line, for instance use with
radio modems.
Disabled*: The communicator expects a connection to the PSTN.
Enabled:
The communicator detects a fault when there is a
voltage lower than 10 V.
ARC settings
Go
to
the
F-Link
software - ARC
communicator position choose a format of ADM-CID or SIA-DCS.
These
protocols
can
be
communicator.
You can find a description of protocols in the "JA-100 CID and
SIA protocol structure". The communicator is able to be used as a
backup for communication to ARCs.
The communicator sends reports to the ARC from the oldest
report to the newest when the telephone number has been set and
ARC transfer is allowed. Every report is recorded in the event
memory (example: "ARC 1, Event report 12523 delivered", which
means the event with the number 12523 in the event memory was
delivered to ARC 1).
LED indicator activity:
Red
– indicates communicator activity;
- Permanently
(communication established)
- Flashes (irregularly): incoming call is detected
Yellow
– indicates faults;
- Permanently lit: telephone line is not available
- Fast flashing: when the module is initialized (a
very short time). Flashing in a normal state means
a fault with communication; the LED will flash all
the time while the fault is still triggered. For more
details see F-Link software.
JA-190X Telephone PSTN communication module
tab.
For
a
selected
transmitted
using
the
JA-190X
lit:
communication
running

Technical specifications

Dialling method
Phone line check
Voice message phone numbers with JA-101K
Voice message phone numbers with JA-106K
Classification
- according to
EN 50136-1, EN 50136-2, SIA DC-02, SIA DC-05
- average humidity
- alarm transmission class – voice
- alarm transmission class – digital
- digital data protocols
Weight
Analogue interface connectivity according to
Also complies with
JABLOTRON ALARMS a.s. hereby declares that the JA-190X
module is in compliance with the essential requirements and other
relevant provisions of directives no. 2014/30/EU, 2014/35/EU,
2011/65/EU. The original of the conformity assessment can be
found at
www.jablotron.com
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer
after
www.jablotron.com.
2 / 2
optional – enabled / disabled
Security grade 2/environmental class II
EN 50131-1, EN 50131-3, EN 50131-10
75 % RH, non condensation
ADM-CID (DTMF), SIA-DCS (FSK)
EN 301 437,TBR 21
EN 50130-4, EN 55022, EN 60950-1
- Technical Support section
use.
For
more
detailed
information
MMD51104
DTMF
8
15
ATS 2
ATS 4
28 g