2.
The current phone call reporting is terminated.
3.
Unfinished SMS and call reports are erased (they are not transmitted
after the service has finished).
4.
Unsent ARC reports are only erased if ARC tel. numbers / IP
addresses / URLs or the ARC communication format or the installation
ID are changed.
5.
Fault restoration reports are sent to the ARC even in service mode.
6.
Changes to communicator settings do not take effect until service
mode has been exited.
8.4. Remote access via the Internet
The system can be accessed remotely via OLink 2.0.1 and higher. This allows
complete programming by installers (it is necessary to know the service code) and
also operating the system by end users in the same way as if they were using a
keypad. To access the system remotely it is necessary to have:
 The communicator registration code xxxxx-xxxxx-xxxx. The code is stated
on the label on the communicator board, in the OLink application or you
can have it sent to you by SMS (see 6.23)
 The telephone number of the communicator SIM card
 The remote access password (see 6.24)
 When GPRS is not available a connection with OLink can be realized by
SMS with limited capabilities. After GPRS has been restored, the system
automatically starts to use the GPRS connection.
It is not possible to register the communicator on www.gsmlink.cz. Remote
access via the Internet is done by the program OLink 2.0.1 or higher.
8.5. Time synchronizing process
The right and accurate time is taken from the GSM network via received SMS
messages or from the Jablotron YTUN server when GPRS is active. When the
communicator has not got time synchronization information, it sends an SMS to
itself via the GSM network (1x per 10 days). There is one requirement, the
communicator must have its own SIM card number saved in position 0 by the
sequence 81 0 xxx..x *0 (xxx..x = own telephone number). If you change the SIM
card, position 0 will be automatically erased.
Time synchronization (see section 6.17) of the control panel is performed
whenever entering into service mode or maintenance mode, and if there is a
difference greater than 5 minutes between the correct time and control panel time,
synchronization is performed automatically in an unset system without needing to
manually change modes.
Notes:
 Synchronization is indicated by a keypad beep
 PG outputs are deactivated during time synchronization, then the outputs
are reactivated afterwards.
 A time synchronization event is sent to the ARC by automatically entering
service/maintenance mode (even when unset) and CID report code 1625
(625 means a time and date reset based on the norm DC-05) is transmitted
before exiting service/maintenance mode.
The JA-82Y GSM communicator installers manual

9. Technical specifications

Power
Stand-by consumption (mean value)
GSM band
Complies in configuration CIE OASIS system with
as follows:
Operating environment – indoor general (-10°C to 40°C)
Security
Safety
EMC
Radio transmissions
CLIP protocol (caller ID + SMS)
Can be operated according to
JABLOTRON ALARMS a.s. hereby declares that the JA-82Y is in
compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC. The original of the conformity
assessment can be found at www.jablotron.com - Technical
Support section
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use. More detailed information
can be found at www.jablotron.com - Technical Support
section
8/13
12V DC (from the control panel)
(depends on the GSM signal strength)
QUAD-BAND, 850/900/1800/1900MHz
EN 50131-1, EN 50136-2-1
ATS 4, ATS 5 if CID protocol is used
and the repeating period is set to zero (Sequence 06p0)
ETSI EN 301489-1, ETSI EN 301489-7
EN 55022, EN 50130-4
ETSI EN 301419-1 and EN 301511
about 35 mA
Class II
Grade 2
EN 60950-1
ETSI EN 300 089
GSM Regulations
MDL51109