B
A
Fig. 4-15
Removing the bottom thermal insulation
INFORMATION
The thermal insulation is installed in reverse order.
4.4.6

Opening the vent valve

1
Removing the thermal insulation (see
2
Open the vent valve on the pump by one turn.
Fig. 4-16
Opening the vent valve
4.4.7
Aligning the connections of the heating
inflow and return flow
CAUTION
When working on the hydraulics, pay attention to the in-
stallation position of the O-rings to avoid damaging them
and causing leaks.
▪ Always place O-rings on the part to be inserted after dis-
assembly or before assembly (see
▪ The heating lines must be connected free of tension via
the plug connectors. Establish a suitable strain relief es-
pecially when connecting with flexible lines (not open to
diffusion!) (see ).
Daikin Altherma EHS(X/H)(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1444099_01 – 11/2018 – EN
Chap.
4.4.5).
Fig.
4-18).
4
CAUTION
If the plug brackets cannot be put on properly, the coup-
lings can be detached from their mountings to ensure a
very strong or continuous escape of liquid can occur.
▪ Before putting on a plug bracket, make sure that the stir-
rup engages in the coupling groove. To do so, insert the
coupling far enough into the mounting that the groove is
visible through the plug bracket mounting.
▪ Insert the plug bracket up to the end stop.
The connections of the heating inflow and return flow can be direc-
ted upwards or backwards in order to adapt it optimally to the struc-
tural conditions of the installation site.
The device is supplied with upwards aligned connections as stand-
ard. The following conversion steps are required in order to direct
the connections to the rear out of the device:
1
Remove the protective cover and top thermal insulation
(see Chap.
4.4.2).
Fig. 4-17
Aligning the heating inflow and return flow upwards
2
Pull the two plug brackets off the connection couplings
(Fig.
4-17, item C).
3
Pull off the two connection couplings
Fig. 4-18
Hydraulic system plug connectors
4
Remove the retaining plate
(Fig.
5
Pull off the sealing plug bracket
6
Pull out the sealing plug
(Fig.
7
Turn the elbow
(Fig.
4-17, item H) 90° to the rear.
8
Pull the plug bracket off the manifold
Set-up and installation
(Fig.
4-17, item B).
4-17, item A).
(Fig.
4-17, item D).
4-17, item E).
(Fig.
4-17, item G).
Installation and maintenance instructions