CONTROLLER PARAMETERS
to
HACCP alarm indicator / reset
'tu
weekday on which the HA event occurred
'th
hours at which the HA event occurred
't'
minutes at which the HA event occurred
|tu
weekday on which the HF event occurred
|th
hours at which the HF event occurred
|t'
minutes at which the HF event occurred
tr
HACCP alarm delay
¯t1
day of defrost event no.1
-t1
hours of defrost event no. 1
_t1
minutes of defrost event no.1
...
....
¯t6
day of defrost event no.6
-t6
hours of defrost event no. 6
_t6
minutes of defrost event no.6
tM
current minutes
th
current hours
td
current day of the week
to: indicatore / reset allarme HACCP
Questo parametro se posto a 1 indica l'attivazione di un errore HACCP,
programmandolo a 0 viene resettato l'allarme.
Nei terminali di tipo LARGE, la stessa funzione si ottiene premendo
per 5 sec. il tasto HACCP.
-Def : 0
'tu, 'th, 't': giorno, ora, minuto in cui è avvenuto l'evento HA
Questi parametri di sola lettura indicano quando è avvenuto l'allarme HA.
- Def : -
|tu, |th, |t': giorno, ora, minuto in cui è avvenuto l'evento HF
Questi parametri di sola lettura indicano quando è avvenuto l'allarme HA.
- Def : -
tr: ritardo allarme HACCP
Tempo (in minuti) che sommato al ritardo Ad determina l'intervallo di
tempo, trascorso il quale, viene visualizzato l'errore HA.
Se impostato a 0, il monitoraggio HACCP è disabilitato.
- Def : 0
¯t1, -t1, _t1: giorno, ora, minuto del primo evento di defrost
È possibile impostare un totale di sei eventi di defrost collegati
all'orologio di sistema RTC.
Il parametro ¯t1 imposta il giorno dell'evento nel seguente modo:
0 = nessun evento
1..7 = lunedi..domenica
8 = da lunedi a venerdi
9 = sabato a domenica
10 = tutti I giorni
Con -t1, _t1 si impostano ora e minuto dell'evento.
- Def : 0, 0, 0 disabilitato
...
¯t6, -t6, _t6: giorno, ora, min. del sesto evento di defrost (come sopra)
tM, th, td: minuti , ora e giorno correnti
Questi parametri hanno effetto immediato, ovvero vengono salvati
indipendentemente dalla pressione di 5 sec. del tasto SET.
L'orologio viene verificato ad ogni accensione dello strumento, se
vengono trovati valori non validi viene ripristinato l'orario
programmandolo a 00:00 e giorno 1, e verrà attivato l'errore tC.
Per eliminare l'errore tC basta regolare l'orologio tramite gli opportuni
parametri.
Nota: Se appare l'errore tC e poi si spegne il sistema alla riaccensione
l'errore tC non sarà più presente perché corretto dalla precedente
accensione.
- Disponibile nei modelli dotati di RTC.

4.11 t = HACCP, clock and timed defrost parameters

Type
Min
C
0
C
1
C
0
C
0
C
1
C
0
C
0
C
0
C
0
C
0
C
0
...
...
C
0
C
0
C
0
C
0
C
0
C
1
to: indicator / reset HACCP alarm
If set to 1, this parameter indicates that an HACCP error, setting it to 0
resets the alarm.
In the LARGE terminals, the same function is achieved by pressing the
HACCP button for 5 seconds.
-Def : 0
'tu, 'th, 't': day, hours, minutes at which the HA event occurred
These read-only parameters indicate when the HA alarm occurred.
- Def : -
|tu, |th, |t': day, hours, minutes at which the HF event occurred
These read-only parameters indicate when the HF alarm occurred.
- Def : -
tr: HACCP alarm delay
Time (in minutes) which, added to the time To, determines the delay in
the signalling of the HA error.
If set to 0, HACCP monitoring is disabled.
- Def : 0
¯t1, -t1, _t1: day, hours, minutes of the first defrost event
A total of six defrost events can be set, connected to the system clock.
The parameter ¯t1 sets the day of the event, as follows:
0 = no event
1..7 = Monday ..Sunday
8 = from Monday to Friday
9 = Saturday to Sunday
10 = all days
The parameters -t1, _t1 set the hours and minutes of the event.
- Def : 0, 0, 0 disabled
...
¯t6, -t6, _t6: day, hours, minutes of the first defrost event (as above)
tM, th, td: current minutes, hours and day
These parameters are immediate, that is, are saved even without pres-
sing SET for 5 seconds.
The clock is checked each time the instrument is switched on, if invalid
values are found, the clock is reset to 00:00 and day 1, and the error tC
is signalled. To remove the tC error, simply set the clock using the
corresponding parameters.
Note: If the error tC appears and then the system is switched off, when
switched back on again the tC error will no longer be present, as it will
have been corrected by the previous start-up.
- Available on models fitted with RTC
37
powerSplit manual - cod. +030220320 rel. 1.1 - 09/12/02
Max
UOM
Def.
1
-
0
7
-
0
23
hours
0
59
mins
0
7
-
0
23
hours
0
59
mins
0
199
mins
0
10
-
0
23
hours
0
59
mins
0
...
...
...
10
-
0
23
hours
0
59
mins
0
59
mins
-
23
hours
-
7
-
-