Cleaning And Maintenance - Foster EP700F Original Operation Instructions

Cabinet & counter models controller & display versions fd1-11 & fd1-14
Hide thumbs Also See for EP700F:
Table of Contents

Advertisement

GB
Loading and Airflow
Ensure that there is no more than 40kg of evenly distribute product placed on or within each shelf or drawer.
Always ensure the air can circulate around/through the stored product.
It is important that for optimal energy performance that adequate airflow is maintained around the perimeter of the
shelves, and around all stored products.
On all models please ensure that no product is placed on the unit base.
Door & Drawer Lock
To lock the door or drawer insert the key and turn 90°, turn in the opposite direction to unlock.
Defrost
All Foster G2 cabinets are fitted with a fully automatic defrost system to ensure that the evaporator coil remains
free from ice during normal use. Melt-water is evaporated using either the heat from the refrigeration system or a
separate electric heater (dependent upon model and configuration)
To activate a manual defrost - while the cabinet is in 'run' mode press and hold
seconds the display will go blank then return after a further 2 seconds. At this point a defrost will be performed
(subject to underlying operating parameters), this will terminate automatically.

Cleaning and Maintenance

Important: Before cleaning, the unit should be put into standby and then the power supply should be
turned off at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has
been completed and the unit is dry should the cabinet be turned back on at the mains.
Suitable P.P.E (Personal Protective Equipment) should be worn at all times.
Regular Maintenance:
>
As
and when required remove all product and shelving (beware of cold and or sharp components) from
the unit. Clean exterior and interior surfaces with mild liquid detergent, following the directions on the
pack at all times. Rinse surfaces with a damp cloth containing clean water. Never use wire wool, scouring
pads/powders or high alkaline cleaning agents i.e bleaches, acids and chlorines as these may cause
damage.
>
All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a warm
damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry.
>
Shelves and their supports can be removed for cleaning. The shelves are dishwasher safe; however the
vertical supports should be cleaned with warm soapy water then rinsed and dried.
>
Condenser Cleaning
Maintenance should take place on a regular basis or as and when required by a competent/trained
personnel.
Traditional Fin
Coil
5
4 to 6
+Stayclear
for 5 seconds. After 3
Coil