Important Note To The Installer; General Electrical Safety; Disposal Requirements; Start-Up And Operation - Foster EP700F Original Operation Instructions

Cabinet & counter models controller & display versions fd1-11 & fd1-14
Hide thumbs Also See for EP700F:
Table of Contents

Advertisement

GB

Important Note to the Installer:

Please ensure that this document is passed to the user as it contains
important guidelines on operation, loading, cleaning and general
maintenance and should be kept for reference.

General Electrical Safety

Foster Refrigerator recommends that the equipment is electrically connected via a Residual Current Device; such
as a Residual Current Circuit Breaker (RCCB) type socket, or through a Residual Current Circuit Breaker with
Overload Protection (RCBO) supplied circuit.

Disposal Requirements

If not disposed of properly all refrigerators have components that can be harmful to the environment. All old
refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance
with national laws and regulations.

Start-Up and Operation

After unpacking, clean and allow the cabinet or counter to stand for 2 hours before turning on (cleaning
directions supplied within this manual). Ensure the cabinet is situated on a firm, level surface away from both
hot and cold air sources, as this will affect its performance.
Vaporiser Tray (Dual Temperature Models Only)
On delivery, the tray is attached to the rear of the cabinet. Remove the two fixing screws and slide the vaporiser
tray underneath the cabinet, into the two fixed runners.
Bend the corner tabs of the tray upwards, then using the guide holes already in the cabinet secure the tray in
position with the two screws originally removed.
The heaters electrical connection to the cabinet will already be in place. Ensure the drain line pipe is angled in an
upright position to form an air lock.
Please make sure that when positioning a dual temperature model with an external vaporiser tray the tray does
not come into contact with any other surfaces.
Clearance (All models)
Make sure that a minimum clearance of 310mm above and 50mm around the
ventilation and effective operation.
Connect the unit to a suitable mains power outlet and turn the supply on. Please do not plug or unplug the unit
with wet hands.
The cabinet will energise briefly showing
The unit is now in standby.
Standby
Pressing the power switch for 3 seconds will turn the unit on (the switch backlight is static and the display shows
the operating temperature) or into standby (the switch backlight pulses slowly on and off).
As the operating temperature has been preset no adjustments are required. Allow the cabinet to reach its normal/
set operating temperature before loading.
followed by the power switch slowly pulsing with a blank display.
cabinet or counter
is available for
2