DC Volts

Ranges
400mV, 4V, 40V, 400V, 600V
Input impedance: 400mV: >100Me; 4V: 10Me; 40V ~ 600V: 9.1Me
Overload protection: 600VDC or AC rms
AC Volts (50Hz - 500Hz)
Ranges
4V, 40V, 400V
600V
Input impedance: 4V: 10Me; 40V ~ 600V: 9.1Me
Overload protection: 600VDC or AC rms
AC Current (50Hz - 60Hz)
Ranges
40A, 400A
Overload protection: 400AAC

Resistance

Ranges
400e, 4ke, 40ke, 400ke
4Me
40Me
Open circuit volts: -0.45V dc typical, (-1.2Vdc on 400e range)
Overload protection: 600VDC or AC rms
Resolution
0.1mV
Resolution
Accuracy
1mV
±(1.2% rdg + 5 dgts) on 4V to 400V ranges
1mV
±(1.5% rdg + 5 dgts) on 600V range
Resolution
0.01A
Resolution
0.1e
0.1e
0.1e
Accuracy
±(0.5% rdg + 2 dgts)
Accuracy
±(2.0% rdg + 6 dgts)
Accuracy
±(1.0% rdg + 4 dgts)
±(1.5% rdg + 4 dgts)
±(3.0% rdg + 5 dgts)