UM-S1P Electric High-Pressure Airless Paint Station
Pressure Release Procedure
Perform the pressure release procedure when shutting the equipment down for any
purpose, including cleaning or adjusting.
1. Turn the spray trigger safety lock on.
2. Rotate the pressure valve left (anti-clockwise)
until fully out.
3. Switch the machine off, and then place the spray valve in the "prime" position (lever facing down).
Prime Position
Spray Position
4. Squeeze the spray trigger to release any remaining pressure in gun.