5. Remove the protective backplane cap as shown in "Removing the
Protective Caps" on page 7.
6. Once attached to the DIN rail, slide modules to the left to mate with
the repeater adapter or another repeater module.
ATTENTION: Make certain that the adapter and repeater
modules are secured together with DIN rail anchors.
!
Failure to do so may result in the loss of communications
and/or cause damage to the modules.
The total number of modules that can be attached to the repeater adapter
can not exceed four or the total power consumption of the modules can
not exceed 1.6A @ 5VDC, whichever comes first.
Important: If you exceed the module or power limit, you may cause
damage to the repeater adapter and modules.
Important: If this is the right–most module, a DIN rail latch must be
used on the right–side of the fiber module.
7. Connect the module wiring as shown in "Wiring The Fiber Module"
on page 8.
1786-5.11 — February 1998
30043–M