INSTALLATION
Water Pressure
Electrical Facilities
Existing Plumbing
Location of System and Drain
Installation Locations
Bypass Valves
Water pressure is not to exceed 125 psi (8.6 bar),
CAUTION
water temperature is not to exceed 110°F (43°C),
and the unit cannot be subjected to freezing
conditions.
The system must be depressurized before
WARNING:
removing any connections for servicing.
Installation Instructions
NOTE: The tank should have the distributor tube installed
and have the proper amount of regenerant in place.
Air Gap
Drain
If grid plate is used, cut air check height just below
CAUTION
the grid plate. This is critical on 6", 7", 8" and 9"
tanks. The brine refill water must come above the
grid plate and make contact with the salt.
NOTE: All electrical connections must be connected according
to local codes. Be certain the outlet is uninterrupted.
Electrical Connection
NOTE: The power source should be constant. Be certain
the power adapter is not on a switched outlet. Power
interruptions longer than eight hours may cause the
controller to lose the time setting. When power is restored,
the time setting must then be re-entered.
FLECK