JOB SPECIFICATION SHEET

Job Number: ___________________________________________________
Model Number: _________________________________________________
Water Hardness: ________________________________________________
ppm or gpg
Capacity Per Unit: ______________________________________________
Mineral Tank Size: _____________ Diameter: ________
Height: __________
Salt Setting per Regeneration: ____________________________________
1. Type of Timer:
A. 7 Day or 12 Day
B. Meter Initiated
2. Downflow:
Upflow
3. Meter Size:
A. 3/4-inch Std Range (125 - 2,100 gallon setting)
B. 3/4-inch Ext Range (625 - 10,625 gallon setting)
C. 1-inch Std Range (310 - 5,270 gallon setting)
D. 1-inch Ext Range (1,150 - 26,350 gallon setting)
E. 1 1/2 inch Std Range (625 - 10,625 gallon setting)
F. 1 1/2 inch Ext Range (3,125 - 53,125 gallon setting)
G. 2-inch Std Range (1,250 - 21,250 gallon setting)
H. 2-inch Ext Range (6,250 - 106,250 gallon setting)
I. 3-inch Std Range (3,750 - 63,750 gallon setting)
J. 3-inch Ext Range (18,750 - 318,750 gallon setting)
K. Electronic ____Pulse Count ___ Meter Size ____________
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration
B. System #4: Time Clock
C. System #4: Twin Tank
D. System #5: 2-5 Tanks, Interlock Mechanical
2-4 Tanks, Interlock Electronic
Meter per unit for Mechanical and Electronic
E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration, Mechanical 2-4
Tanks, 1 Meter, Series Regeneration, Electronic
F. System #7: 2-5 Tanks, 1 Meter, Alternating
Regeneration,Mechanical 2 Tanks only, 1 Meter,
Alternating Regeneration, Electronic
G. System #9: Electronic Only, 2-4 Tanks, Meter per Valve, Alternating
H. System #14: Electronic Only, 2-4 Tanks, Meter per Valve. Brings
units on and offline based on flow.
5. V alve Operating Parameters:
M odels: 2500, 2510, 2750, 2850
Minimum operating pressure:
Maximum operating pressure:
Minimum water temperature:
Maximum water temperature:
Maximum Ambient temperature:
Maximum humidity:
Input Voltage:
Maximum Watts:
Maximum altitude:
6. Timer Program Settings:
A. Backwash: Minutes
B. Brine and Slow Rinse: _________________________ Minutes
C. Rapid Rinse: _________________________________ Minutes
Upflow Variable
20 psi / 1.4 bar / 138 kPa
125 psi / 8.61 bar / 861 kPa
34° F / 1° C
110° F / 43° C
120° F / 52° C
75%
120 Volts AC / 60 Hz
30 watts
2000 meters
D. Brine Tank Refill: _____________________________ Minutes
E. Pause Time: _________________________________ Minutes
F. Second Backwash: ____________________________ Minutes
7. Drain Line Flow Control:
8. Brine Line Flow Controller:
9. Injector Size#:
10. Piston Type:
A. Hard Water Bypass
B. No Hard Water Bypass

INSTALLATION

Water Pressure
A minimum of 20 pounds (1.4 bar) of water pressure is required
for regeneration valve to operate effectively.
Electrical Warnings & Caution Statement
An uninterrupted alternating current (A/C) supply is required.
NOTE: Other voltages are available. Please make sure your
voltage supply is compatible with your unit
before installation.
Grounding Instructions
This appliance must be grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
appliance is equipped with a cord having an appliance-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances.
Improper connection of the appliance-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service representative if you
are in doubt whether the appliance is properly
grounded. Do not modify the plug provided with
the appliance; if it will not fit the outlet, have a
proper outlet installed by a qualified technician.
Risk of electric shock. Disconnect power before
servicing.
FOR DRY LOCATIONS USE ONLY.
The cover should only be removed during installation set-up and
maintenance by a qualified service person.
Existing Plumbing
Condition of existing plumbing
should be free from lime and
iron buildup. Piping that is built
up heavily with lime and/or iron
should be replaced. If piping is
clogged with iron, a separate
iron filter unit should be installed
ahead of the water softener.
Location of Softener and Drain
The softener should be located close to the drain to prevent air
breaks and back flow. You must have an air gap on the drain line
to prevent back flow of drain water into the system. The air gap
should be two (2) times the diameter of the drain line pipe but
must be at least 1-inch.
FLECK
gpm
gpm
Air Gap
Drain
2850 Control Valve Service Manual
• 3