Preventive Maintenance Schedule - Bunn JDF-2S Service & Repair Manual

Hide thumbs Also See for JDF-2S:
Table of Contents

Advertisement

REQUIRED REGULAR MAINTENANCE:
When performing Daily-Weekly Cleaning procedures, inspect o-rings, seals, and bushings for signs of wear or
damage and replace immediately.
Check and/or replace every 6 months or as required:
39690.0000
28755.1011
32732.0000
32656.0000
21275.0003
34325.0032
Pump Tube Replacement Kit (Includes items indented below)
Tube, Norprene .25" ID x 17.0" lg
Clamp .39"/.48"
Fitting, Elbow .25" Barb x .38" Barb
Clamp .57"/.70"
Hose, Flex .38" ID x 5.25" lg
5